Wiring Diagram - Mitsubishi Electric PLFY-P32VBM-E Technical & Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PLFY-P32VBM-E:
Table of Contents

Advertisement

7

WIRING DIAGRAM

PLFY-P32/40/50/63/80/100/125VBM-E.UK
PLFY-P32/40/50/63/80VBM-E
PLFY-P32/40/50/63/80/100/125VBM-ER2.UK
[LEGEND]
SYMBOL
NAME
I. B
INDOOR CONTROLLER BOARD
CN27
CONNECTOR DAMPER
REMOTE SWITCH
CN32
CENTRALLY CONTROL
CN51
CN52
REMOTE INDICATION
FUSE
FUSE (T6.3AL250V)
POWER SUPPLY (I. B)
LED1
LED2
POWER SUPPLY (I. B)
SW2
SWITCH
CAPACITY CODE
MODE SELECTION
SW3
SW4
MODEL SELECTION
SWE
DRAIN PUMP (TEST MODE)
X1
AUX. RELAY
DRAIN PUMP
DP
DRAIN PUMP
FS
DRAIN FLOAT SWITCH
LEV
LINEAR EXPANSION VALVE
MF
FAN MOTOR
MV
VANE MOTOR
A.B
GRILLE
MV MV MV MV
M
M
M
M
5
5
5
5
20
18
16
14
12
10
19
17
15
13
11
9
i-SEE SENSOR MOTOR
CN6Y
1
(RED)
6
MA REMOCON
1
i-SEE SENSOR
CN4Y
(WHT)
1
4
LEV
CN60
1
(WHT)
CN52
(GRN)
1
5
1
6
4
5
M
I-SEE
SENSOR
MT
M
I-SEE SENSOR CORNER PANEL
(OPTIONAL PART)
LEV
NOTES:
1. At servicing for outdoor unit, always follow the wiring diagram of outdoor unit.
2. In case of using MA-Remote controller, please connect to TB15.
(Remote controller wire is non-polar.)
3. In case of using M-NET, please connect to TB5. (Transmission line is non-polar.)
4. Symbol [S] of TB5 is the shield wire connection.
5. Symbols used in wiring diagram above are,
6. The setting of the SW2 dip switches differs in the capacity. For the detail, refer to fig *1.
LED on indoor board for service
Mark
LED1 Main power supply
Power supply for MA-Remote controller
LED2
OCH413D
.UK
1
SYMBOL
TB2
TB5
TB15
TH21
TH22
TH23
A. B
SWA
SWB
SWC
SW1
SW11
SW12
SW14
4
(RED)
ADDRESS
CN43
SWA
SWB
1
8
SW1
3
2
ON
2
3
OFF
1
4
(RED)
12345678910
ADDRESS
SW12
SW11
SW14
CN82
SWC
10ths
1s
BRANCH
1
DIGIT
DIGIT
No.
8
CN32
J42J41
(WHT)
8
6
4
2
1
3
1
Pair No.
7
5
3
1
ADDRESS
VANE CNV
CN81
(WHT)
(RED)
LED2
CN3A
WIRELESS
(BLU)
CN90
3
(WHT)
1
6
CN41
CN51
(WHT)
(WHT)
5
1
4
9
TB15
BLU
TO MA-REMOTE
CNB
1
BLU
CONTROLLER
2
DC8.7-13V
SW1
SW2
RU
W.B
: terminal block,
Meaning
Power supply for MA-Remote controller on
NAME
TERMINAL
POWER SUPPLY
BLOCK
TRANSMISSION
MA-REMOTE CONTROLLER
ROOM TEMP. DETECTION
THERMISTOR
(0
/ 15k , 25
PIPE TEMP. DETECTION / LIQUID
(0
/ 15k , 25
PIPE TEMP. DETECTION / GAS
(0
/ 15k , 25
ADDRESS BOARD
SWITCH
CEILING HEIGHT SELECTOR
DISCHARGE OUTLET NUMBER
SELECTOR
OPTION SELECTOR
MODE SELECTION
ADDRESS SETTING 1s DIGIT
ADDRESS SETTING 10ths DIGIT
BRANCH NO.
<fig. *1> The black square (■) indicates a switch position.
MODELS
SW2
MODELS
ON
P32
P80
OFF
1 2 3 4 5 6
ON
P40
P100
OFF
1 2 3 4 5 6
ON
P50
P125
OFF
1 2 3 4 5 6
ON
P63
OFF
1 2 3 4 5 6
See fig.*1
4
SW3
SW4
SW2
ON
OFF
8
1
4
12345678910
12345
123456
ADDRESS
CN42
SWE
(RED)
OFF
ON
3
9
CN25
1
3
(WHT)
AUTO GRILLE
1
2
CN3G
LED1
(BLK)
INTAKE
LIQUID/PIPE
FLOAT SW
CN27
CN20
CN44
CN4F
(RED)
(RED)
(WHT)
(WHT)
1
4
1
4
1
2
1
BZ
LED2
LED1
TH22
TH23
FS
TH21
: connecter.
Function
Main Power supply (Indoor unit:220-240V) power on
22
SYMBOL
OPTION PART
W.B
PCB FOR WIRELESS REMOTE CONTROLLER
BZ
BUZZER
LED1
LED (OPERATION INDICATION : GREEN)
/ 5.4k )
LED2
LED (PREPARATION FOR HEATING : ORANGE)
RU
RECEVING UNIT
/ 5.4k )
SW1
EMERGENCY OPERATION (HEAT / DOWN)
SW2
EMERGENCY OPERATION (COOL / UP)
/ 5.4k )
SW2
TB5
TO OUTDOOR UNIT
BLU
ON
M1
BC CONTROLLER
OFF
BLU
REMOTE CONTROLLER
M2
1 2 3 4 5 6
DC24-30V
S
(SHIELD)
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
1 3 5
ON
2 1
OFF
M-NET
CN2M
(BLU)
DC311~339V
RECTIFICATION
FUSE
FAN
X1
CNMF
(WHT)
D.U.M
3
1
2
7
4
1
CNP
(BLU)
M
MS
1~
3~
DP
MF
* Be sure to turn off the power
AUTOMATIC FILTER ELEVATION PANEL
source and then disconnect
(OPTIONAL PART)
fan motor connector.
(Failure to do so will cause
trouble in Fan motor.)
Lamp is lit.
Lamp is lit.
NAME
POWER SUPPLY
~/N 220-240V 50Hz
220V 60Hz
BREAKER
(16A)
FUSE(16A)
TB2
RED
PULL BOX
L
BLU
N
GRN/YLW
TO NEXT
INDOOR UNIT
I.B
CND
(BLK)
AUTO GRILLE POWER
CNAC
(WHT)
3
1
3
U.B
3
1
5 3
1
CN3G
CN3A