Problem
The Start indicator light
flashes slowly and the
display is dark.
The Clean out airways
indicator light comes on
at the end of a pro‐
gramme.
The programme is can‐
celled and the Clean
out airways indicator
light comes on.
Bars flash in the display
at the end of a pro‐
gramme:
.........
 lights up
Cause and remedy
The dryer is in standby mode. This is a normal func‐
tion and does not indicate a fault.
 See "Standby" in "Programmable functions".
There is a build-up of fluff in the airways.
 Clean the fine filter.
 Clean the fluff filters
 Open and close the door while the dryer is switch‐
ed on. The indicator light will go out.
An excessive amount of fluff has built up.
 Clean the fine filter, fluff filter and heat exchanger.
 Open and close the door while the dryer is switch‐
ed on. The indicator light will go out.
The programme has finished but the laundry has not
yet cooled down.
 Either remove the laundry and spread it out to cool
down or leave it in the tumble dryer to cool down
during the cooling phase.
The programme selector has been moved.
 Select the original programme. The time remaining
will appear in the display again.