PERFORMANCE DATA

*SZC160241A* / CA*F3636*6**+TXV / MBVC1600**-1**
Conditions: 80° IDB, 67° IWB @ 600 CFM, LOW STAGE
Outdoor
Total
Sensible
Temp. ° F.
Btuh
75°
18,965
80°
18,739
85°
18,513
90°
18,287
95°
18,062
100°
17,610
105°
17,158
110°
16,526
115°
15,894
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
95°
16737
*SZ C160481A* / CA*F4961*6**+TXV / M BV C2000**-1**
Con ditio ns : 80° IDB, 67° IWB @ 1100 CFM , LOW ST AGE
Outdoor
Total
Sensible
Tem p. ° F.
Btuh
75°
36,151
80°
35,721
85°
35,290
90°
34,860
95°
34,430
100°
33,569
105°
32,708
110°
31,503
115°
30,298
TV A Co nditions @ 95° OD DB, 75° ID DB, 63° ID WB
95°
31,904
*SZC160601B* / CA*F4860*6A*+TXV/ MBVC2000**-1
Conditions: 80°F IDB, 67°F IWB @ 1200 CFM LOW STAGE
Outdoor
Total
Temp. ° F.
Btuh
75°
42,221
80°
41,718
85°
41,215
90°
40,713
95°
40,210
100°
39,205
105°
38,200
110°
36,792
115°
35,385
TVA Conditions @ 95° OD DB, 75° OD DB. 63° OD WB
95°
37,260
28
Latent
Total
Btuh
Btuh
Watts
14,056
4,908
1,223
14,065
4,673
1,263
14,070
4,443
1,303
14,123
4,165
1,338
14,170
3,892
1,373
14,077
3,533
1,403
13,971
3,187
1,433
13,513
3,013
1,459
13,050
2,844
1,485
14028
2709
1317
Latent
Total
Btuh
Btuh
W atts
25,245
10,906
2,254
25,261
10,459
2,328
25,270
10,020
2,402
25,364
9,496
2,467
25,448
8,981
2,532
25,282
8,286
2,587
25,092
7,616
2,643
24,269
7,234
2,691
23,438
6,860
2,739
25,194
6,710
2,428
Sensible
Latent
Total
Btuh
Btuh
Watts
28,720
13,501
2,729
28,734
12,984
2,817
28,749
12,467
2,906
28,850
11,863
2,983
28,951
11,259
3,061
28,749
10,456
3,127
28,546
9,654
3,193
27,605
9,187
3,250
26,664
8,721
3,307
28,662
8,599
2,938
*SZC160361A* / CA*F3743*6**+TXV / MBVC1600**-1**
Conditions: 80° IDB, 67° IWB @ 800 CFM, LOW STAGE
Outdoor
Total
Sensible
Temp. ° F.
Btuh
75°
26,493
80°
26,177
85°
25,862
90°
25,546
95°
25,231
100°
24,600
105°
23,969
110°
23,086
115°
22,203
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
95°
23,380
*SZC160601A* / CA*F4961*6**+TXV / MBVC2000**-1**
Conditions: 80° IDB, 67° IWB @ 1200 CFM, LOW STAGE
Outdoor
Total
Sensible
Temp. ° F.
Btuh
75°
42,671
80°
42,163
85°
41,655
90°
41,147
95°
40,639
100°
39,623
105°
38,607
110°
37,185
115°
35,762
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
95°
37,658
LOW STAGE
Latent
Total
Btuh
Btuh
Watts
18,600
7,892
1,656
18,612
7,565
1,710
18,619
7,243
1,764
18,688
6,858
1,811
18,750
6,481
1,858
18,628
5,972
1,898
18,488
5,482
1,938
17,881
5,205
1,973
17,269
4,934
2,008
18,563
4,817
1,783
Latent
Total
Btuh
Btuh
Watts
29,080
13,591
2,828
29,099
13,064
2,924
29,109
12,546
3,019
29,218
11,929
3,103
29,315
11,324
3,187
29,123
10,500
3,258
28,904
9,703
3,330
27,956
9,229
3,392
26,999
8,764
3,453
29,021
8,636
3,054