4. COMPONENT OUT Pb Level Adjustment
(TT-003 board)
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Pb signal terminal of COMPONENT
OUT jack (75 Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
94
Pb level: A = 525 ± 10 mVp-p
Specified value
Sync level: B = C = 300 ± 10 mVp-p
Switch setting:
1) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
1
0
01
01
2
3
71
01
3
0
10
01
8
4
00
(18)
5
0
10
00
6
C
94
7
C
94
8
9
0
10
01
8
00
10
(18)
11
0
10
00
12
3
70
10
13
3
70
14
0
01
00
Note: For the bit values, refer to "6-4. SERVICE MODE", "4-4.
3. Bit value discrimination".
B
C
Fig. 6-3-8
HVR-V1J/V1U/V1N/V1E/V1P/V1C
Procedure
Press PAUSE (Write) button.
Set the bit value of bit7 is
"1", and press PAUSE
(Write) button. (Note)
Change the data and set the
Pb signal level (A) to the
specified value.
Press PAUSE (Write) button.
Check the sync signal (B, C)
to the specified value.
Set the bit value of bit7 is
"0", and press PAUSE
(Write) button. (Note)
Press PAUSE (Write) button.
Check the data changes to
"11".
H
A
6-140