ROUTINE MAINTENANCE
SMALL AREA PAINT TOUCH-UP
The stove body is painted with a quality high-
temperature stove paint. Use only Stove Paint, Part #
70K99. Do not touch-up your stove with any other paint.
Using one small piece of 320 grit sand paper and lightly
sand the blemish so that the edges are "feathered" or
smooth to the touch between the painted and bare sur-
faces. Do not let the sand paper gum up with paint, as
this will cause scratches on the metal surface. If there
are any scratches, use 600 grit sandpaper instead. Mask
off surfaces you do not want painted. Paint lightly over
the bare surface first as this will act as an undercoat.
Then paint over a larger area in smooth even strokes to
blend.
MOTOR LUBRICATION
Room Air Blower: The room air blower is permanently
lubricated by the manufacturer. Do not apply oil to any
part of the blower, doing so may cause damage.
Exhaust Blower: The exhaust blower requires lubrica-
tion every 6 months or yearly, depending on use, with not
more than two drops of 30 weight, SAE, nondetergent oil
at the two lubrication points on blower.