CLEARANCES - MODEL CI2000HT
COMBUSTIBLE WALL CLEARANCE – USA & Canada
WARNING: It is very important that you observe the minimum
clearances.
There are listed clearances for your stove which were determined in a
Laboratory test using various "classes" of stove pipe or chimney. Mini-
mums are first established for the stove itself and increased based on
how much heat is transferred by each class of pipe.
Position the unit no closer than the minimum clearances to combustible
materials. Check that no overhead cross members in the ceiling or roof
will be cut. Reposition unit if necessary being careful not to move closer
than the minimum clearances.
Single Wall Pipe - CI2000HT
(Not approved for alcove installations)
Using single wall 24 MSG black or 25 MSG blued steel connector pipe
with factory-built chimney listed to either UL 103HT or ULC S629.
Minimum Clearances to Combustibles - inches (millimeters)
A
18" (457 mm)
B
32" (813 mm)
C
27" (686 mm)
G
35-3/16" (894 mm) This is a reference dimension only
Table 6 (see Figures 3 and 4)
Double Wall Pipe - CI2000HT
(For alcove installations, clearances "C" and "F" are not applicable) Use
listed double wall chimney connector or Type L vent pipe to the top of
the stove.
Minimum Clearances to Combustibles - inches (millimeters)
A
14-1/2" (368 mm)
B
28-1/2" (724 mm)
C
18" (457 mm)
Table 7 (see Figures 3 and 4)
Minimum Ceiling Height for Single wall pipe and double wall pipe instal-
lations and Alcove Installations – 60" (1524 mm) from floor to ceiling
and 29" (737 mm) from stove top to ceiling.
Alcove Installation Clearances - CI2000HT
Alcove Installations Require Double Wall Pipe Only
Use listed double wall chimney connector or Type L vent pipe to the top
of the stove.
Minimum Clearances to Combustibles - inches (millimeters)
A
14-1/2" (368 mm)
B
28-1/2" (724 mm)
C
N/A
Table 8 (see Figures 3 and 4)
Note: Alcove clearances cannot be reduced using wall protection. Maxi-
mum alcove depth must be no more than 48" (1220 mm).
D
13" (330 mm)
E
20" (508 mm)
F
16" (406 mm)
D
10" (254 mm)
E
17" (432 mm)
F
7" (178 mm)
D
10" (254 mm)
E
17" (432 mm)
F
N/A
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Combustible
E
B
Figure 3 - Parallel Installation
Combustible
G
B
Figure 4 - Corner Installation
MODEL CI1000HT IS NOT APPROVED FOR USE WITH DOUBLE
WALL PIPE.
DO NOT INSTALL THE CI1000HT INTO AN ALCOVE OR A CONFINED
SPACE. This unit has not been tested or approved for installation
into a confined space such as an alcove (see the national standard
below).
NFPA 211- latest edition: (Applies to Solid Fuel Burning Appliances,
which are not alcove tested) - Solid fuel-burning appliances shall
not be installed in confined spaces. The space or room shall be of
ample size to allow adequate circulation of heated air. Appliances
shall be so located as not to interfere with the proper circulation
of air within the heated space.
Installing Leg Pads
The four leg pads (included in accessory package), are provided for
placement under the four legs.
D
A
F
C
9