TROUBLE DIAGNOSIS
In Crush Mode,
Is the voltage between
pin2 of CON5 and pin11
of CON3 like as below,
while pushing the lever
switch?
CON5
Pin1
Output voltage of auger motor
Level switch
Test Point
Pushing
pin1 To pin11
Normal
pin1 To pin11
Yes
In Crush Mode,
Is the voltage between
pin1 and pin5 of CON5
like as below, while
pushing the lever switch?
Pin5
Output voltage of dispenser solenoid
Level switch
Test Point
Pushing
pin1 To pin5
Normal
pin1 To pin5
Yes
Replace
No
Main PCB
CON3
Pin11
Result
230 V
0 ~ 2V
Replace
No
Main PCB
Pin1
Result
230 V
0 ~ 2V
Is the resistance value
between (1) and (2) of the
Auger motor like as below?
(1)
(2)
Resistance of Auger Motor at 25℃
Test Point
(1) To (2)
Yes
Is the resistance value
between (1) and (2) of the
Cube solenoid like as
below?
Resistance of Cube solenoid
Test Point
(1) To (2)
Yes
Replace
No
Auger Motor
Result
12.3 ~ 20.1 Ω
Replace
No
Cube
Solenoid
(1)
(2)
Result
156.8 ~ 173.3 Ω