Smeg GW-P227 Service Manual page 35

Sxs refrigerator
Table of Contents

Advertisement

TROUBLE DIAGNOSIS
In Crush Mode,
Is the voltage between
pin1 and pin5 of CON5
like as below, while
pushing the lever switch?
Pin5
Output voltage of dispenser solenoid
Level switch
Pushing
pin1 To pin5
Normal
pin1 To pin5
Yes
Is the resistance value
between (1) and (2) of the
Auger motor like as below?
(1)(2)
Test Point
(1) To (2)
Yes
Replace
No
Main PCB
Pin1
Test Point
Result
230 V
0 ~ 2V
Replace
No
Auger Motor
Result
12.3 ~ 15.1 Ω
Is the resistance between
(1) and (2) of the
Dispenser solenoid like as
below?
Resistance of Dispenser solenoid
Test Point
283 ~328 Ω
(1) To (2)
Yes
Is the condition of
the micro switch like as
below?
(1)
(2)
Status
Normal
Push the Lever
Yes
After plug in,
explain to the customer!
Replace
Dispenser
No
Solenoid
(1)
(2)
Result
Replace
No
Micro
Switch
Tester
Infinity
0 Ω

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gw-l227

Table of Contents