Lincoln Electric INVERTEC 160SX Operator's Manual page 8

Hide thumbs Also See for INVERTEC 160SX:
Table of Contents

Advertisement

A. Power Switch: It turns ON / OFF the input power to
the machine.
B. Input cable: This machine is provided with a plugged
input cord. Connect it to the mains.
C. Fan: This machine has a F.A.N. (Fan As Needed)
circuitry inside. The machine automatically turns it
ON or OFF. This feature reduces the amount of dirt
which can be drawn inside the machine and reduces
power consumption. When the machine is turned ON
the fan will turn ON. The fan will continue to run
whenever the machine is welding. The F.A.N. feature
is active after that the machine doesn't weld for more
than 10 minutes, the fan will be turned OFF and, at
same time, the output will be disabled. To restore the
output and the fan, simply restart to weld.
English
Maintenance
For any repair operations, modifications or
maintenances, it is recommended to contact the nearest
Technical Service Center or Lincoln Electric. Repairs
and modifications performed by unauthorized service or
personnel will cause, that the manufacturer's warranty
will become null and void.
Any noticeable damage should be reported immediately
and repaired.
Routine maintenance (everyday)
Check condition of insulation and connections of the
work leads and insulation of power lead. If any
insulation damage exists replace the lead
immediately.
Remove the spatters from the welding gun nozzle.
Spatters could interfere with the shielding gas flow to
the arc.
Check the welding gun condition: replace it, if
necessary.
Check condition and operation of the cooling fan.
Keep clean its airflow slots.
Periodic maintenance (every 200 working hours but
at list once every year)
Perform the routine maintenance and, in addition:
Keep the machine clean. Using a dry (and low
pressure) airflow, remove the dust from the external
case and from the cabinet inside.
If it is required, clean and tighten all weld terminals.
The frequency of the maintenance operations may vary
in accordance with the working environment where the
machine is placed.
Do not touch electrically live parts.
Before the case of welding machine will be removed, the
welding machine had to be turned off and the power lead
had to be disconnected from mains socket.
Mains supply network must be disconnected from the
machine before each maintenance and service. After
each repair, perform proper tests to ensure safety.
5