Technical Specifications

INVERTEC
INVERTEC
Input Voltage Range
from 115 to 230Vac ±15% (CE model)
240Vac ±15% (AUS model)
Single Phase (CE/AUS model)
Duty Cycle (@ Input Voltage)
(Based on a 10 min. period)
100% (@ 115Vac)
30% (@ 115Vac)
CE model
100% (@ 115Vac)
30% (@ 115Vac)
100% (@ 230/240Vac)
CE/AUS model
30% (@ 230/240Vac)
AUS model
100% (@ 240Vac)
(10A Circuit)
25% (@ 240Vac)
Welding Current Range
160SX / 160SX AUS
Fuse (delayed) or
Circuit Breaker ("D" characteristic)
160SX CE
160SX AUS
Height
244mm
Operating Temperature
-10°C to +40°C
English
NAME
®
160SX CE
®
160SX AUS
Input Power at Rated Output
3.07kVA @ 100% Duty Cycle
5.17kVA @
RATED OUTPUT AT 40°C
OUTPUT RANGE
5 – 160A
RECOMMENDED INPUT CABLE AND FUSE SIZES
Input Power Cable
16A
10A
PHYSICAL DIMENSIONS
Width
148mm
INPUT
30% Duty Cycle
Output Current
70A
100A
100A
150A
100A
160A
90A
160A
Maximum Open Circuit Voltage
2
3 x 2.5mm
2
3 x 1.5mm
Length
385mm
Storage Temperature
7
INDEX
K12050-1
K12050-2
EMC Group /
Class
Frequency
II / A
Output Voltage
22.8Vdc (Stick)
24.0Vdc (Stick)
14.0Vdc (TIG)
16.0Vdc (TIG)
24.0Vdc (Stick) – 14.0Vdc (TIG)
26.4Vdc (Stick) – 16.4Vdc (TIG)
23.6Vdc (Stick) – 13.6Vdc (TIG)
26.4Vdc (Stick) – 16.4Vdc (TIG)
≤80Vdc (CE model)
32Vdc (AUS model)
Type of Plug
(Included with Machine)
---
AUS 10A-250V
Weight
9.0kg
-25°C to +55°C
50/60Hz