Preparation For Inspection / Adjustment Of Main Pcb - Nikon ED 17-55mm f/2.8G IF Repair Manual

Af-s dx zoom-nikkor jaa78851
Table of Contents

Advertisement

INC
JAA78851-R.3617.A

PREPARATION FOR INSPECTION / ADJUSTMENT OF MAIN PCB

●In case of replacing the main PCB, SWM unit or MR encoder unit, be sure to make the necessary
adjustments as follows:
1. Adjustments
 ・Adjust the MR duty
 ・Adjust the driving frequency and motor control
2. Equipment and tools to be required
 ・Single output rated voltage power supply: 1 unit ( 6.0V 3.0A)
 ・Oscilloscope: 1 unit
For adjusting the MR duty, the driving frequency and motor control
 ・AF-I communication box (J15306-1): 1 unit
 ・AF-I communication adapter (J15307): 1 unit
- L44 ・ AF-S DX17-55/2.8G -