Adjustment
13

Knee lever stop

.04.07
13 - 8
Requirement
When knee lever 3 has been moved as far as possible, the presser foot should rise
approx. 9 mm above the needle plate.
Fig. 13 - 07
Adjust screw 1 (nut 2) in accordance with the requirement.
3
1
0
2