Saeco Minuto Service Manual page 81

Hide thumbs Also See for Minuto:
Table of Contents

Advertisement

MINUTO
Level 1 (Key)
Start condition: NO BU, NO drag drawer,
Door open, No Water in tank, Coffee Beans
cover open
Action by user
Switch on Red Leds NoWater & GenAlarm
ERROR: Led NoWater remains off, check
the interface board and fl at cable (JP21)
ERROR: Led Dreg remains off, check the
interface board and fl at cable (JP21)
ERROR: Led NoWater & Dreg remain off,
check the interface board and fl at cable
(JP21)
Action by user
Switch on Orange Leds Descale & Rinsing
ERROR: Led Descale remains off, check the
interface board and fl at cable (JP21)
ERROR: Led Rinsing remains off, check the in-
terface board and fl at cable (JP21)
ERROR: Led Descale & Rinsing remain off,
check the interface board and fl at cable
(JP21)
Action by user
Switch on Red Leds Dreg & NoBeans
ERROR: Led NoBeans remains off, check
the interface board and fl at cable (JP21)
ERROR:Led GenAlarm remains off, check
the interface board and fl at cable (JP21)
ERROR:Led NoBeans & GenAlarm remain
off, check the interface board and fl at cable
(JP21)
Led
Led
NoBeans
NoWater
OFF
OFF
Press Espresso Button
Led
Led
NoBeans
NoWater
OFF
ON
OFF
ON
OFF
Press CalcCLean Button
Led
Led
NoBeans
NoWater
OFF
OFF
Press Coffee Button
Led
Led
NoBeans
NoWater
ON
OFF
OFF
ON
OFF
05 TROUBLESHOOTING
LED INDICATION
Led
Led
GenAlarm
Dreg
OFF
OFF
LED INDICATION
Led
Led
GenAlarm
Dreg
OFF
ON
ON
OFF
OFF
LED INDICATION
Led
Led
GenAlarm
Dreg
OFF
OFF
LED INDICATION
Led
Led
GenAlarm
Dreg
ON
OFF
ON
OFF
OFF
Led
Led
Descale
Rinsing
OFF
OFF
Led
Led
Descale
Rinsing
OFF
OFF
Led
Led
Descale
Rinsing
ON
ON
OFF
ON
ON
OFF
OFF
OFF
Led
Led
Descale
Rinsing
OFF
OFF