Baxi windermere TF Installation And Servicing Instrucnions page 22

Hide thumbs Also See for windermere TF:
Table of Contents

Advertisement

10.0 Changing Components – Page 22
Supplied By www.heating spares.co Tel. 0161 620 6677
10.5 Electrode (Fig. 48)
1.
Pull the lead off the electrode and undo the two screws
holding the pilot retaining plate.
2.
Note the orientation of the electrode, withdraw it and
refit the new component in reverse order of dismantling.
10.6 Thermocouple (Figs. 48 & 49)
1.
Undo the thermocouple nut from the interrupter unit and
remove the two screws holding the pilot retaining plate.
2.
Remove the thermocouple and shape the new one in a
similar manner to the original.
3.
Fit the new component in reverse order of dismantling.
10.7 Pilot Burner and Injector (Fig. 48)
1.
Undo the pilot feed pipe nut from the pilot injector.
2.
Undo the two screws holding the pilot assembly
retaining plate, noting the orientation of the pilot burner
outlet ports.
3.
Withdraw the pilot injector and burner. The injector can
now be removed from the burner.
4.
Replace either or both components as required and
reassembly in reverse order of dismantling.
10.8 Burner (Fig. 50)
1.
Remove all other control components as described in
sections 10.3 through to 10.7.
2.
Fit all the previously removed control components to
the new burner.
3.
Reassemble all components in reverse order and
recommission the appliance.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Windermere rfGrasmere rfGrasmere tf