PROBLEM
Unit fails to heat up. Lighted On/
Off Switch DOES NOT illuminate
when set to "ON" position.
Unit fails to heat up. Lighted On/
Off Switch DOES illuminate when
set to "ON" position.
Steam output is weak or
intermittent.
Excessive amount of water in
steam.
NOTE: Unit produces wet steam
– it is normal for steam to
contain some amount of water.
Accessories do not stay firmly
connected to Main Nozzle.
Floor surfaces appear cloudy or
streaky after steaming.

Troubleshooting

POSSIBLE CAUSE
Unit is not plugged in.
Household circuit breaker / ground
fault interrupter has tripped or
blown a fuse.
Unit is damaged or otherwise in
need of repair.
Water Reservoir is empty.
Mineral build-up in unit.
Unit is damaged or otherwise in
need of repair.
Water level in Water Reservoir is
running low.
Mineral build-up in unit.
Water condensation in Steam
Hose.
Water Reservoir has been
overfilled.
Unit has not heated to full
operating temperature.
Accessories not properly installed.
Microfiber Pad is dirty.
Hard water residue on floor.
SOLUTION
Plug power cord into electrical outlet.
Reset circuit breaker / ground
fault interrupter, or replace fuse.
If you need assistance, contact a
licensed electrician.
Immediately cease usage and
unplug. Contact Consumer
Service for further assistance
(see Page 16 for details).
Refer to Filling Water Reservoir
procedure on Page 11.
Refer to Mineral Build-up section
on Page 14 for cleaning procedure.
Immediately cease usage and
unplug. Contact Consumer
Service for further assistance
(see Page 16 for details).
Refer to Filling Water Reservoir
procedure on Page 11.
Refer to Mineral Build-up section
on Page 14 for cleaning procedure.
Point nozzle towards sink, tub or
ground and shake while pressing
Steam Button. Continue until
excess water is released.
Filling Water Reservoir with more
than 48 oz. (1,420 ml.) of water
interferes with steam production,
resulting in water condensation
in steam.
Always use included Measuring
Cup to fill unit with correct amount
of water. (see Page 11 for details)
Wait until Steam Ready Light
turns off to begin steaming.
Check to make sure that acces-
sories are properly connected, per
procedures on Pages 6-9.
Replace Microfiber Pad with a
clean one.
Switch to distilled or
de-mineralized water.
ENGLISH | 15