Motorola Symbol DS6707 Product Reference Manual

Motorola Symbol DS6707 Product Reference Manual

Motorola symbol ds6707 digital imager scanner
Hide thumbs Also See for Symbol DS6707:
Table of Contents

Advertisement

Symbol DS6707 Digital
Imager Scanner
Product Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Motorola Symbol DS6707

  • Page 1 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 3 Symbol DS6707 Digital Imager Scanner Product Reference Guide 72E-83978-04 Revision A August 2008...
  • Page 4 Motorola. No right to copy a licensed program in whole or in part is granted, except as permitted under copyright law. The user shall not modify, merge, or incorporate any form or portion of a licensed program with other program material, create a derivative work from a licensed program, or use a licensed program in a network without written permission from Motorola.
  • Page 5: Revision History

    Revision History Changes to the original manual are listed below: Change Date Description -01 Rev A 8/2006 Initial Release. -02 Rev A 4/2007 Updated service information, updated operating temperature and drop specifications, added Host Trigger Mode option, added new UPC/EAN supplemental options, changed RSS references to GS1 DataBar, added following parameters: Illumination Bank Control, Fixed Exposure, Fixed Gain, Gain/Exposure Priority for Snapshot Mode, Image Brightness, JPEG Target...
  • Page 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 7: Table Of Contents

    Scanning with the Digital Imager Scanner .............. 2-4 Aiming ........................2-6 Scanning in Presentation Mode ..................2-7 Decode Zones ......................2-8 Symbol DS6707-SR Standard Range Digital Imager Scanner - 1D Bar Codes ..2-8 Symbol DS6707-SR Standard Range Digital Imager Scanner - 2D Bar Codes ..2-9...
  • Page 8 Symbol DS6707-DP Direct Part Mark Digital Imager Scanner - 1D and PDF417 Bar Codes ..................2-12 Symbol DS6707-DP Direct Part Mark Digital Imager Scanner - 2D Bar Codes ..2-13 Symbol DS6707-HD High Density Digital Imager Scanner - 1D and PDF417 Bar Codes ..................2-14 Symbol DS6707-HD High Density Digital Imager Scanner - 2D Bar Codes ...
  • Page 9 Table of Contents Errors While Scanning ....................5-2 Imaging Preferences Parameter Defaults ..............5-2 Imaging Preferences ..................... 5-4 Operational Modes ....................5-4 Low Light Enhancement ..................5-5 Presentation Mode Field of View ................5-5 Image Capture Autoexposure ................. 5-6 Image Capture Illumination ..................5-6 Illumination Bank Control ..................
  • Page 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide Interpacket Delay ....................6-13 Event Reporting ......................6-14 Decode Event ......................6-14 Boot Up Event ......................6-15 Parameter Event ..................... 6-15 Chapter 7: USB Interface Introduction ........................7-1 Connecting a USB Interface ..................7-2 USB Parameter Defaults ....................
  • Page 11 Table of Contents Chapter 9: 123Scan Introduction ........................9-1 123Scan Parameter ...................... 9-1 Chapter 10: Symbologies Introduction ........................10-1 Scanning Sequence Examples ..................10-1 Errors While Scanning ....................10-2 Symbology Parameter Defaults ..................10-2 UPC/EAN ........................10-7 Enable/Disable UPC-A .................... 10-7 Enable/Disable UPC-E ....................
  • Page 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide Enable/Disable Interleaved 2 of 5 ................10-40 Set Lengths for Interleaved 2 of 5 ................10-40 I 2 of 5 Check Digit Verification ................10-42 Transmit I 2 of 5 Check Digit ................... 10-42 Convert I 2 of 5 to EAN-13 ..................
  • Page 13 Table of Contents QR Code ......................... 10-68 MicroQR ........................10-69 QR Inverse ......................10-70 Aztec ........................10-71 Aztec Inverse ......................10-72 Redundancy Level ......................10-73 Redundancy Level 1 ....................10-73 Redundancy Level 2 ....................10-73 Redundancy Level 3 ....................10-73 Redundancy Level 4 ....................
  • Page 14 Symbol DS6707 Digital Imager Scanner Product Reference Guide Turn On/Off Rule Sets .................... 11-88 Alphanumeric Keyboard ....................11-90 Appendix A: Standard Default Parameters Appendix B: Programming Reference Symbol Code Identifiers ....................B-1 AIM Code Identifiers ..................... B-3 Appendix C: Sample Bar Codes Code 39 ........................
  • Page 15: About This Guide

    About This Guide Introduction The Symbol DS6707 Digital Imager Scanner Product Reference Guide provides general instructions for setting up, operating, maintaining, and troubleshooting the Symbol DS6707 digital imager scanner. Configurations This guide includes the following digital imager scanner configurations: •...
  • Page 16: Notational Conventions

    Symbol DS6707 Digital Imager Scanner Product Reference Guide • Chapter 6, SSI Interface describes how to set up the digital imager scanner with a Simple Serial Interface (SSI) host. When using SSI, program the digital imager scanner via bar code menu or SSI host commands.
  • Page 17: Related Documents

    Software type and version number Motorola responds to calls by e-mail, telephone or fax within the time limits set forth in service agreements. If your problem cannot be solved by Motorola Enterprise Mobility Support, you may need to return your equipment for servicing and will be given specific directions.
  • Page 18: Chapter 1 Getting Started

    Chapter 1 Getting Started Introduction The Symbol DS6707 digital imager scanner combines superior 1D and 2D omnidirectional bar code scanning and sub-second image capture and transfer to provide the best value in a digital imager scanner. Whether in hand-held mode or presentation (hands-free) mode in a stand, the digital imager scanner ensures comfort and ease of use for extended periods of time.
  • Page 19: Supported Interfaces

    Configuration via 123Scan. Unpacking Remove the digital imager scanner from its packing and inspect it for damage. If the scanner was damaged in transit, contact Motorola Enterprise Mobility Support. See page xv for contact information. KEEP THE PACKING. It is the approved shipping container; use this to return the equipment for servicing.
  • Page 20: Setting Up The Digital Imager Scanner

    1 - 3 Symbol DS6707 Digital Imager Scanner Product Reference Guide Setting Up the Digital Imager Scanner Installing the Interface Cable Plug the interface cable modular connector into the cable interface port on the bottom of the scanner handle. Figure 1-2.
  • Page 21: Connecting Power (If Required)

    Getting Started 1 - 4 Connecting Power (if required) If the host does not provide power to the digital imager scanner, connect an external power supply: Connect the interface cable to the bottom of the digital imager scanner, as described in Installing the Interface Cable on page 1-3.
  • Page 22: Wall Mount

    1 - 5 Symbol DS6707 Digital Imager Scanner Product Reference Guide Wall Mount To use the optional wall mount to mount the digital imager scanner on a wall, place the mount in the desired location on the wall and secure by inserting two screws* appropriate for the mounting surface through the screw holes on the mount, and into the surface.
  • Page 23: Chapter 2 Scanning

    Chapter 2 Scanning Introduction This chapter provides beeper and LED definitions, techniques involved in scanning bar codes, general instructions and tips about scanning, and decode zone diagrams. Beeper Scan Window Trigger Parts Figure 2-1...
  • Page 24: Beeper Definitions

    2 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Beeper Definitions The digital imager scanner issues different beep sequences and patterns to indicate status. Table 2-1 defines beep sequences that occur during both normal scanning and while programming the digital imager scanner.
  • Page 25 Scanning 2 - 3 Beeper Definitions (Continued) Table 2-1 Beeper Sequence Indication Fast warble beep Aborting MPDF sequence. Low/high beeps Flushing an already empty MPDF buffer. ADF Programming: Normal Data Entry. Duration of tones are short. High/low beeps Enter another digit. Add leading zeros to the front if necessary. Low/low beeps Enter another alphabetic character or scan the End of Message bar code.
  • Page 26: Led Definitions

    Install and program the digital imager scanner (see Setting Up the Digital Imager Scanner on page 1-3). For assistance, contact the local supplier or Motorola Enterprise Mobility Support. Scanning with the Digital Imager Scanner Ensure all connections are secure (see the appropriate host chapter.) Aim the digital imager scanner at the bar code.
  • Page 27 Scanning 2 - 5 When the digital imager scanner senses movement, in its default Auto Aim trigger mode, it projects a red laser aiming pattern (Figure 2-3) which allows positioning the bar code or object within the field of view. (To turn off the default Auto Aim trigger mode, see Trigger Mode on page 4-8.) If necessary, the digital imager scanner...
  • Page 28: Aiming

    2 - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide Aiming Hold the digital imager scanner between two and nine inches (depending on symbol density; see Decode Zones on page 2-8) from the symbol, centering the aiming pattern on the symbol. Ensure the cross hair falls on the symbol.
  • Page 29: Scanning In Presentation Mode

    Scanning 2 - 7 Scanning in Presentation Mode The optional Intellistand adds greater flexibility to scanning operation. When you insert the digital imager scanner into the stand’s “cup,” the scanner’s built-in sensor places the scanner in presentation (hands-free) mode. When you remove the digital imager scanner from the stand it operates in its normal hand-held mode.
  • Page 30: Decode Zones

    2 - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide Decode Zones Symbol DS6707-SR Standard Range Digital Imager Scanner - 1D Bar Codes Note: Typical performance at 73.4 F (23 C) on high quality symbols. In . 3 1 .6 12.7...
  • Page 31: Symbol Ds6707-Sr Standard Range Digital Imager Scanner - 2D Bar Codes

    Scanning 2 - 9 Symbol DS6707-SR Standard Range Digital Imager Scanner - 2D Bar Codes Note: Typical performance at 73.4 F (23 C) on high quality symbols. In . 3 1 .6 12.7 DS6707-SR 12.7 6.6 mil PDF417 25.4 10 mil QR Code...
  • Page 32: Symbol Ds6707-Dc Document Capture Digital Imager Scanner - 1D Bar Codes

    10 mil I 2 of 5 38.1 13 mil (100% UPC/EAN) 14.7 20 mil (Code 39) 21.4 In . 12.7 25.4 38.1 50.8 63.5 Depth of Field Symbol DS6707-DC Document Capture Digital Imager Scanner Decode Zone for 1D Bar Codes Figure 2-10...
  • Page 33: Symbol Ds6707-Dc Document Capture Digital Imager Scanner - 2D Bar Codes

    10 mil MicroPDF 19.1 PDF417 (10 mil) 11.1 Datamatrix (10 mil) 12.2 35 mil Maxicode 12.8 In . 12.5 12.7 19.1 25.4 31.8 38.1 Depth of Field Symbol DS6707-DC Document Capture Digital Imager Scanner Decode Zone for 2D Bar Codes Figure 2-11...
  • Page 34: Symbol Ds6707-Dp Direct Part Mark Digital Imager Scanner - 1D And Pdf417 Bar Codes

    2 - 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide Symbol DS6707-DP Direct Part Mark Digital Imager Scanner - 1D and PDF417 Bar Codes Note: Typical performance at 73.4 F (23 C) on high quality symbols. In . DS6707-DP 3 mil Code 39 1.21...
  • Page 35: Symbol Ds6707-Dp Direct Part Mark Digital Imager Scanner - 2D Bar Codes

    5 mil QR Code 1.25 7.5 mil QR Code 1.67 10 mil QR Code In . 1.27 2.54 3.81 5.08 6.35 Depth of Field Symbol DS6707-DP Direct Part Mark Digital Imager Scanner Decode Zone for 2D Bar Codes Figure 2-13...
  • Page 36: Symbol Ds6707-Hd High Density Digital Imager Scanner - 1D And Pdf417 Bar Codes

    6.67 mil PDF417 3.10 0.63 10 mil PDF417 3.54 0.46 15 mil PDF417 4.46 1.33 In . 10.2 15.2 20.3 Depth of Field Symbol DS6707-HD High Density Digital Imager Scanner Decode Zone for 1D and PDF417 Bar Codes Figure 2-14...
  • Page 37: Symbol Ds6707-Hd High Density Digital Imager Scanner - 2D Bar Codes

    2.54 7.5 mil QR Code 0.67 3.00 10 mil QR Code 0.46 3.42 In . 1.27 2.54 3.81 5.08 6.35 7.62 8.89 Depth of Field Symbol DS6707-HD High Density Digital Imager Scanner Decode Zone for 2D Bar Codes Figure 2-15...
  • Page 38 2 - 16 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 39: Chapter 3 Maintenance & Technical Specifications

    Chapter 3 Maintenance & Technical Specifications Introduction This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts). Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy. • Do not allow abrasive material to touch the window. •...
  • Page 40: Troubleshooting

    3 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Troubleshooting Troubleshooting Table 3-1 Problem Possible Causes Possible Solutions The aiming pattern does not appear No power to the digital imager If the configuration requires a power when pressing the trigger.
  • Page 41 Maintenance & Technical Specifications 3 - 3 Troubleshooting (Continued) Table 3-1 Problem Possible Causes Possible Solutions Digital imager scanner decodes bar Digital imager scanner is not Scan the appropriate host type code, but does not transmit the data to programmed for the correct host type. programming bar code.
  • Page 42: Technical Specifications

    3 - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide NOTE If after performing these checks the digital imager scanner still experiences problems, contact the distributor or contact Motorola Enterprise Mobility Support. See page xv for the telephone numbers.
  • Page 43 Maintenance & Technical Specifications 3 - 5 Technical Specifications (Continued) Table 3-2 Item Description Typical Working Distance: 5 mil Code 39: 0.9 - 5.4 in. (2.3 - 13.7 cm) SR - Standard Range Focus 10 mil I 2 of 5: 1.0 - 7.9 in.
  • Page 44 3 - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide Technical Specifications (Continued) Table 3-2 Item Description Typical Working Distance: 3 mil Code 39: 0.84 - 2.42 in. (2.13 - 6.15 cm) HD - High Density 4 mil Code 39: 0.42 - 3.13 in.
  • Page 45 Maintenance & Technical Specifications 3 - 7 Technical Specifications (Continued) Table 3-2 Item Description User Environment Operating Temperature 32º F to 104º F (0º C to 40º C) Storage Temperature -40º F to 158º F (-40º C to 70º C) Humidity 5% to 95%, non-condensing Drop Specifications...
  • Page 46: Digital Imager Scanner Signal Descriptions

    Digital Imager Scanner Cable Pinouts Figure 3-1 The signal descriptions in Table 3-3 apply to the connectors on the Symbol DS6707 digital imager scanner and are for reference only. Symbol DS6707 Digital Imager Scanner Signal Pin-outs Table 3-3 RS-232/SSI...
  • Page 47: Chapter 4 User Preferences & Miscellaneous Digital Imager Scanner Options

    Chapter 4 User Preferences & Miscellaneous Digital Imager Scanner Options Introduction You can program the digital imager scanner to perform various functions, or activate different features. This chapter describes each user preference feature and provides programming bar codes for selecting these features. The digital imager scanner ships with the settings shown in Table 4-1 on page 4-2 (also see...
  • Page 48: Scanning Sequence Examples

    4 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-5.
  • Page 49 User Preferences & Miscellaneous Digital Imager Scanner Options 4 - 3 User Preferences Parameter Defaults (Continued) Table 4-1 Parameter Page Parameter Default Number Number Beep After Good Decode Enable 4-11 Decoding Illumination F0h, 2Ah Enable 4-11 DP Illumination F1h, 3Bh Auto 4-12 Decode Aiming Pattern...
  • Page 50: User Preferences

    4 - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide User Preferences Set Default Parameter Scan this bar code to return all parameters to the default values listed in Table A-1 on page A-1. Set All Defaults...
  • Page 51: Parameter Scanning

    User Preferences & Miscellaneous Digital Imager Scanner Options 4 - 5 Parameter Scanning Parameter # ECh To disable decoding of parameter bar codes, scan the Disable Parameter Scanning bar code below. Note that the scanner can still decode the Set Defaults parameter bar code. To enable decoding of parameter bar codes, either scan Enable Parameter Scanning or Set All Defaults.
  • Page 52: Beeper Volume

    4 - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide Beeper Volume Parameter # 8Ch To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code. Low Volume (02h) Medium Volume (01h) High Volume...
  • Page 53: Time Delay To Low Power Mode

    User Preferences & Miscellaneous Digital Imager Scanner Options 4 - 7 Time Delay to Low Power Mode Parameter # 92h NOTE This parameter only applies when Power Mode is set to Reduced Power. This parameter sets the time the digital imager scanner remains active after decoding. The digital imager scanner wakes upon trigger pull or when the host attempts to communicate with the digital imager scanner.
  • Page 54: Trigger Mode

    4 - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide Trigger Mode Parameter # 8Ah Select one of the following trigger modes for the digital imager scanner: • Level - A trigger pull activates decode processing. Decode processing continues until the bar code is decoded, the trigger is released, or the Decode Session Timeout is reached.
  • Page 55: Picklist Mode

    User Preferences & Miscellaneous Digital Imager Scanner Options 4 - 9 Picklist Mode Parameter # F0h 92h Picklist mode enables the digital imager scanner to decode only bar codes that are aligned under the laser crosshair. Select one of the following picklist modes for the digital imager scanner: •...
  • Page 56: Decode Session Timeout

    4 - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide Decode Session Timeout Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
  • Page 57: Decoding Illumination

    User Preferences & Miscellaneous Digital Imager Scanner Options 4 - 11 Beep After Good Decode Parameter # 38h Select a bar code below to choose whether or not the digital scanner beeps after a good decode (or image capture in Snapshot mode). If you select Do Not Beep After Good Decode, the beeper still operates during parameter menu scanning and to indicate error conditions.
  • Page 58: Dp Illumination

    4 - 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide DP Illumination (Symbol DS6707-DP Only) Parameter # F1h, 3Bh This parameter controls whether the digital imager scanner uses direct or indirect illumination. Options are: • Auto Illumination: Alternates direct and indirect illumination.
  • Page 59: Decode Aiming Pattern

    User Preferences & Miscellaneous Digital Imager Scanner Options 4 - 13 Decode Aiming Pattern Parameter # F0h, 32h This parameter only applies when in Decode Mode. Select Enable Decode Aiming Pattern to project the aiming pattern during bar code capture, or Disable Decode Aiming Pattern to turn the aiming pattern off. NOTE With picklist enabled, the decode aiming pattern flashes even when the Decode Aiming Pattern is disabled.
  • Page 60: Decode Mirror Images (Data Matrix Only)

    4 - 14 Symbol DS6707 Digital Imager Scanner Product Reference Guide Decode Mirror Images (Data Matrix Only) Parameter # F1h 19h Select an option for decoding mirror image Data Matrix bar codes: • Always - decode only Data Matrix bar codes that are mirror images •...
  • Page 61: Miscellaneous Scanner Parameters

    User Preferences & Miscellaneous Digital Imager Scanner Options 4 - 15 Miscellaneous Scanner Parameters Transmit Code ID Character Parameter # 2Dh A Code ID character identifies the code type of a scanned bar code. This is useful when the digital imager scanner is decoding more than one code type.
  • Page 62: Prefix/Suffix Values

    4 - 16 Symbol DS6707 Digital Imager Scanner Product Reference Guide Prefix/Suffix Values Key Category Parameter # P = 63h, S1 = 62h, S2 = 64h Decimal Value Parameter # P = 69h, S1 = 68h, S2 = 6Ah You can append a prefix and/or one or two suffixes to scan data for use in data editing. To set a value for a prefix or suffix, scan a four-digit number (i.e., four bar codes from...
  • Page 63: Scan Data Transmission Format

    User Preferences & Miscellaneous Digital Imager Scanner Options 4 - 17 Scan Data Transmission Format Parameter # EBh To change the scan data format, scan one of the following bar codes corresponding to the desired format. NOTE If using this parameter, do not use ADF rules to set the prefix/suffix To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 4-16.
  • Page 64: Fn1 Substitution Values

    4 - 18 Symbol DS6707 Digital Imager Scanner Product Reference Guide Scan Data Transmission Format (continued) <PREFIX> <DATA> <SUFFIX 1> (05h) <PREFIX> <DATA> <SUFFIX 2> (06h) <PREFIX> <DATA> <SUFFIX 1> <SUFFIX 2> (07h) FN1 Substitution Values Key Category Parameter # 67h Decimal Value Parameter # 6Dh The Wedge and USB HID Keyboard hosts support a FN1 Substitution feature.
  • Page 65: Transmit "No Read" Message

    User Preferences & Miscellaneous Digital Imager Scanner Options 4 - 19 Transmit “No Read” Message Parameter # 5Eh Scan a bar code below to select whether or not to transmit a No Read message. Enable this to transmit the characters NR when a bar code is not decoded. Disable this to send nothing to the host if a symbol does not decode.
  • Page 66 4 - 20 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 67: Chapter 5 Imaging Preferences

    Chapter 5 Imaging Preferences Introduction You can program the digital imager scanner to perform various functions, or activate different features. This chapter describes imaging preference features and provides programming bar codes for selecting these features. The digital imager scanner ships with the settings in Imaging Preferences Parameter Defaults on page 5-2 (also Appendix A, Standard Default Parameters...
  • Page 68: Scanning Sequence Examples

    5 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Scanning Sequence Examples In most cases scanning one bar code sets the parameter value. For example, to disable the decode aiming pattern, scan the Disable Decode Aiming Pattern bar code under Decode Aiming Pattern on page 4-13.
  • Page 69 Imaging Preferences 5 - 3 Imaging Preferences Parameter Defaults (Continued) Table 5-1 Parameter Page Parameter Default Number Number Snapshot Aiming Pattern F0h 2Ch Enable 5-10 Image Cropping F0h 2Dh Disable 5-11 Crop to Pixel Addresses F4h F0h 3Bh; 0 top, 0 left, 1023 bottom, 5-12 F4h F0h 3Ch;...
  • Page 70: Imaging Preferences

    5 - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide Imaging Preferences The parameters in this chapter control image capture characteristics. Image capture occurs in all modes of operation, including decode, video, and snapshot. Operational Modes The digital imager scanner has three modes of operation: •...
  • Page 71: Low Light Enhancement

    Imaging Preferences 5 - 5 Low Light Enhancement Parameter # F1h, 64h In presentation mode, selecting Enable Low Light Enhancement causes illumination to remain on at a low level in low lighting conditions. Select Disable Low Light Enhancement to prevent illumination from remaining on under these conditions.
  • Page 72: Image Capture Autoexposure

    5 - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide Image Capture Autoexposure Parameter # F0h, 68h Select Enable Image Capture Autoexposure to allow the digital imager scanner to control gain settings and exposure (integration) time to best capture an image for the selected operation mode.
  • Page 73: Illumination Bank Control

    Imaging Preferences 5 - 7 Illumination Bank Control Parameter # F1h, 3Bh This parameter controls the illumination banks on the scan engine. Options are: • Full: Enables the full illumination system (default). • Auto: Switches the illumination system from left to right bank. •...
  • Page 74: Fixed Exposure

    5 - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide Fixed Exposure Parameter #: F4h F1h 37h Type: Word Range: 5 - 5000 This parameter configures the exposure used in manual mode for both Decode and Snapshot/Video/Video viewfinder modes.
  • Page 75: Gain/Exposure Priority For Snapshot Mode

    Imaging Preferences 5 - 9 Gain/Exposure Priority for Snapshot Mode Parameter # F1h, 32h This parameter alters the digital imager scanner’s gain exposure priority when it acquires an image in Snapshot Mode in auto exposure mode. • Scan Low Exposure Priority to set a mode in which the digital imager scanner favors higher gain over exposure to capture an image.
  • Page 76: Snapshot Mode Timeout

    5 - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide Snapshot Mode Timeout Parameter # F0h, 43h This parameter sets the amount of time the digital imager scanner remains in Snapshot Mode. The digital imager scanner exits Snapshot Mode when you pull the trigger, or when the Snapshot Mode Timeout elapses. To set this...
  • Page 77: Image Cropping

    Imaging Preferences 5 - 11 Image Cropping Parameter # F0h, 2Dh This parameter crops a captured image. Select Disable Image Cropping to present the full 1280 x 1024 pixels. Select Enable Image Cropping to crop the image to the pixel addresses set in Crop to Pixel Addresses on page 5-12.
  • Page 78: Crop To Pixel Addresses

    5 - 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide Crop to Pixel Addresses Parameter # F4h, F0h, 3Bh (Top) Parameter # F4h, F0h, 3Ch (Left) Parameter # F4h, F0h, 3Dh (Bottom) Parameter # F4h, F0h, 3Eh (Right) If you selected Enable Image Cropping, set the pixel addresses from (0,0) to (1279,1023) to crop to.
  • Page 79: Image Size (Number Of Pixels)

    Imaging Preferences 5 - 13 Image Size (Number of Pixels) Parameter # F0h, 2Eh This option alters image resolution before compression. Multiple pixels are combined to one pixel, resulting in a smaller image containing the original content with reduced resolution. Select one of the following values: Resolution Uncropped Image Size...
  • Page 80: Image Brightness (Target White)

    5 - 14 Symbol DS6707 Digital Imager Scanner Product Reference Guide Image Brightness (Target White) Parameter # F0h 86h Type: Byte Range: 1 - 240 This parameter sets the Target White value used in Snapshot, Video and Video Viewfinder mode when using auto exposure.
  • Page 81: Jpeg Target File Size

    Imaging Preferences 5 - 15 JPEG Target File Size Parameter # F4h, F1h, 31h Type: Word Range: 5-600 This parameter defines the target JPEG file size in terms 1 Kilobytes (1024 bytes). The default value is 160 kB which represents 160 Kilobytes. CAUTION JPEG compress may take 10 to 15 seconds based on the amount of information in the target image.
  • Page 82: Image Enhancement

    5 - 16 Symbol DS6707 Digital Imager Scanner Product Reference Guide Image Enhancement Parameter # F1h, 34h This parameter configures the digital imager scanner's Image Enhance feature. This feature uses a combination of edge sharpening and contrast enhancement to produce an image that is visually pleasing.
  • Page 83: Image File Format Selector

    Imaging Preferences 5 - 17 Image File Format Selector Parameter # F0h, 30h Select an image format appropriate for the system (BMP, TIFF, or JPEG). The digital imager scanner stores captured images in the selected format. BMP File Format (03h) JPEG File Format (01h) TIFF File Format...
  • Page 84: Bits Per Pixel

    5 - 18 Symbol DS6707 Digital Imager Scanner Product Reference Guide Bits Per Pixel Parameter # F0h, 2Fh Select the number of significant bits per pixel (BPP) to use when capturing an image. Select 1 BPP for a black and white image, 4 BPP to assign 1 of 16 levels of grey to each pixel, or 8 BPP to assign 1 of 256 levels of grey to each pixel.
  • Page 85: Signature Capture

    Imaging Preferences 5 - 19 Signature Capture Parameter # 5Dh A signature capture bar code is a special-purpose symbology which delineates a signature capture area in a document with a machine-readable format. The recognition pattern is variable so it can optionally provide an index to various signatures.
  • Page 86: Signature Capture File Format Selector

    5 - 20 Symbol DS6707 Digital Imager Scanner Product Reference Guide Signature Capture File Format Selector Parameter # F0h, 39h Select a signature file format appropriate for the system (BMP, TIFF, or JPEG). The digital imager scanner stores captured signatures in the selected format.
  • Page 87: Signature Capture Bits Per Pixel

    Imaging Preferences 5 - 21 Signature Capture Bits Per Pixel Parameter # F0h, 3Ah Select the number of significant bits per pixel (BPP) to use when capturing a signature. Select 1 BPP for a black and white image, 4 BPP to assign 1 of 16 levels of grey to each pixel, or 8 BPP to assign 1 of 256 levels of grey to each pixel.
  • Page 88: Signature Capture Width

    5 - 22 Symbol DS6707 Digital Imager Scanner Product Reference Guide Signature Capture Width Parameter # F4h, F0h, 6Eh The aspect ratio of the Signature Capture Width and Signature Capture Height parameters must match that of the signature capture area. For example, a 4 x 1 inch signature capture area would require a 4 to 1 aspect ratio of width to height.
  • Page 89: Video View Finder

    Imaging Preferences 5 - 23 Video View Finder Parameter # F0h, 44h Select Enable Video View Finder to project the video view finder while in Video Mode, or Disable Video View Finder to turn the video view finder off. Disable Video View Finder (00h) Enable Video View Finder (01h)
  • Page 90: Video View Finder Image Size

    5 - 24 Symbol DS6707 Digital Imager Scanner Product Reference Guide Video View Finder Image Size Parameter # F0h, 49h Select the number of 100-byte blocks. Values range from 800 to 3000 bytes. Selecting a smaller value transmits more frames per second; selecting a larger value increases video quality.
  • Page 91: Chapter 6 Ssi Interface

    Chapter 6 SSI Interface Introduction This chapter describes how to set up the digital imager scanner with a Simple Serial Interface (SSI) host. When using SSI, program the digital imager scanner via bar code menu or SSI host commands. Throughout the programming bar code menus, default values are indicated with asterisks ( Baud Rate 9600 Indicates Default Feature/Option...
  • Page 92: Connecting Using Simple Serial Interface

    6 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Connecting Using Simple Serial Interface Connect the digital imager scanner to an SSI host. Interface Cable Serial Port Connector to Host Power Supply Cable SSI Host Connection Figure 6-1...
  • Page 93: Simple Serial Interface Default Parameters

    SSI Interface 6 - 3 Simple Serial Interface Default Parameters Table 6-1 lists the defaults for the SSI host. There are two ways to change the default values: • Scan the appropriate bar codes in this guide. These new values replace the standard default values in memory.
  • Page 94: Ssi Host Parameters

    6 - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide SSI Host Parameters Baud Rate Parameter # 9Ch Baud rate is the number of bits of data transmitted per second. Set the digital imager scanner's baud rate to match the data rate setting of the host device.
  • Page 95 SSI Interface 6 - 5 Baud Rate (continued) Baud Rate 19,200 (07h) 38,400 (08h) 57,600 (0Ah) 115,200 (0Bh) 230,400 (0Ch)
  • Page 96: Parity

    6 - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide Parity Parameter # 9Eh A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. • Select Odd parity to set the parity bit to a value 0 or 1, based on data, to ensure that the coded character contains an odd number of 1 bits.
  • Page 97: Check Parity

    SSI Interface 6 - 7 Check Parity Parameter # 97h Select whether or not to check the parity of received characters. Use the Parity parameter to select the type of parity. Check Parity (01h) Do Not Check Parity (00h) Software Handshaking Parameter # 9Fh This parameter offers control of the data transmission process in addition to that offered by hardware handshaking.
  • Page 98: Host Rts Line State

    6 - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide Host RTS Line State Parameter # 9Ah This parameter sets the expected idle state of the Serial Host RTS line. The SSI Interface is used with host applications which also implement the SSI protocol. However, you can also use the digital imager scanner in a "scan-and-transmit"...
  • Page 99: Stop Bit Select

    SSI Interface 6 - 9 Stop Bit Select Parameter # 9Dh The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving (host) device for the next character in the serial data stream. Set the number of stop bits (one or two) to match host device requirements.
  • Page 100: Host Serial Response Time-Out

    6 - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide Host Serial Response Time-out Parameter # 9Bh This parameter specifies how long the decoder waits for an ACK or NAK before resending. Also, if the decoder wants to send, and the host was already granted permission to send, the decoder waits for the designated time-out before declaring an error.
  • Page 101: Host Character Time-Out

    SSI Interface 6 - 11 Host Character Time-out Parameter # EFh This parameter determines the maximum time the decoder waits between characters transmitted by the host before discarding the received data and declaring an error. To set the delay period (options are 200, 500, 750, or 990 ms), scan one of the following bar codes. NOTE Other values are available via SSI command.
  • Page 102: Multipacket Option

    6 - 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide Multipacket Option Parameter # F0h, 4Eh This parameter controls ACK/NAK handshaking for multi-packet transmissions. • Multi-Packet Option 1: The host sends an ACK / NAK for each data packet during a multi-packet transmission.
  • Page 103: Interpacket Delay

    SSI Interface 6 - 13 Interpacket Delay Parameter # F0h, 4Fh This parameter specifies the interpacket delay when Multipacket Option 3 is selected. To set the delay period (options are 0, 25, 50, 75, or 99 ms), scan one of the following bar codes. NOTE Other values are available via SSI command.
  • Page 104: Event Reporting

    6 - 14 Symbol DS6707 Digital Imager Scanner Product Reference Guide Event Reporting The host can request the digital imager scanner to provide certain information (events) relative to the digital imager scanner’s behavior. Enable or disable the events listed in...
  • Page 105: Boot Up Event

    SSI Interface 6 - 15 Boot Up Event Parameter # F0h, 02h When enabled, the digital imager scanner generates a message to the host when power is applied. When disabled, no notification is sent. Enable Boot Up Event (01h) Disable Boot Up Event (00h) Parameter Event Parameter # F0h, 03h...
  • Page 106 6 - 16 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 107: Chapter 7 Usb Interface

    Chapter 7 USB Interface Introduction This chapter describes how to set up the digital imager scanner with a USB host. The digital imager scanner connects directly to a USB host, or a powered USB hub, which powers it. No additional power supply is required. Throughout the programming bar code menus, asterisks ( ) indicate default values.
  • Page 108: Connecting A Usb Interface

    7 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Connecting a USB Interface Interface Cable USB Series A Connector USB Connection Figure 7-1 The digital imager scanner connects with USB-capable hosts including: • Desktop PCs and notebooks • Apple™ iMac, G4, iBooks (North America only) •...
  • Page 109: Usb Parameter Defaults

    USB Interface 7 - 3 USB Parameter Defaults Table 7-1 lists the defaults for USB host parameters. To change an option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 7-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
  • Page 110: Usb Host Parameters

    7 - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide USB Host Parameters USB Device Type Select the desired USB device type. NOTE When changing USB Device Types, the digital imager scanner automatically resets and issues the standard startup beep sequences.
  • Page 111: Symbol Native Api (Snapi) Status Handshaking

    USB Interface 7 - 5 USB Device Type (continued) Symbol Native API (SNAPI) with Imaging Interface Symbol Native API (SNAPI) without Imaging Interface Symbol Native API (SNAPI) Status Handshaking After selecting a SNAPI interface as the USB device type, select whether to enable or disable status handshaking. Enable SNAPI Status Handshaking Disable SNAPI Status Handshaking...
  • Page 112: Usb Country Keyboard Types (Country Codes)

    7 - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide USB Country Keyboard Types (Country Codes) Scan the bar code corresponding to the keyboard type. This setting applies only to the USB HID Keyboard Emulation device. NOTE When changing USB country keyboard types the digital imager scanner automatically resets and issues the standard startup beep sequences.
  • Page 113 USB Interface 7 - 7 USB Country Keyboard Types (continued) Spanish Windows Italian Windows Swedish Windows UK English Windows Japanese Windows (ASCII) Portuguese-Brazilian Windows...
  • Page 114: Usb Keystroke Delay

    7 - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide USB Keystroke Delay This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan a bar code below to increase the delay when hosts require slower data transmission. No Delay...
  • Page 115: Usb Ignore Unknown Characters

    USB Interface 7 - 9 USB Ignore Unknown Characters This option applies only to the HID Keyboard Emulation device and IBM device. Unknown characters are characters the host does not recognize. Select Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters.
  • Page 116: Emulate Keypad With Leading Zero

    7 - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide Emulate Keypad with Leading Zero Enable this to send character sequences sent over the numeric keypad as ISO characters which have a leading zero. For example ASCII A transmits as “ALT MAKE” 0 0 6 5 “ALT BREAK”.
  • Page 117: Function Key Mapping

    USB Interface 7 - 11 Function Key Mapping ASCII values under 32 are normally sent as a control-key sequences (see Table 7-2 on page 7-13). Enable this to send the keys in bold in place of the standard key mapping. Table entries that do not have a bold entry remain the same whether or not you enable this parameter.
  • Page 118: Convert Case

    7 - 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide Convert Case Enable this to convert all bar code data to the selected case. No Case Conversion Convert All to Upper Case Convert All to Lower Case...
  • Page 119: Ascii Character Set For Usb

    USB Interface 7 - 13 ASCII Character Set for USB USB Prefix/Suffix Values Table 7-2 Prefix/ Suffix Full ASCII Code 39 Keystroke Value Encode Char.acter 1000 CTRL 2 1001 CTRL A 1002 CTRL B 1003 CTRL C 1004 CTRL D 1005 CTRL E 1006...
  • Page 120 7 - 14 Symbol DS6707 Digital Imager Scanner Product Reference Guide USB Prefix/Suffix Values (Continued) Table 7-2 Prefix/ Suffix Full ASCII Code 39 Keystroke Value Encode Char.acter 1025 CTRL Y 1026 CTRL Z 1027 CTRL [/ESC 1028 CTRL \ 1029...
  • Page 121 USB Interface 7 - 15 USB Prefix/Suffix Values (Continued) Table 7-2 Prefix/ Suffix Full ASCII Code 39 Keystroke Value Encode Char.acter 1053 1054 1055 1056 1057 1058 1059 1060 < 1061 1062 > 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072...
  • Page 122 7 - 16 Symbol DS6707 Digital Imager Scanner Product Reference Guide USB Prefix/Suffix Values (Continued) Table 7-2 Prefix/ Suffix Full ASCII Code 39 Keystroke Value Encode Char.acter 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093...
  • Page 123 USB Interface 7 - 17 USB Prefix/Suffix Values (Continued) Table 7-2 Prefix/ Suffix Full ASCII Code 39 Keystroke Value Encode Char.acter 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 The keystroke in bold transmits only if you enabled Function Key Mapping on page 7-11.
  • Page 124 7 - 18 Symbol DS6707 Digital Imager Scanner Product Reference Guide USB ALT Key Character Set (Continued) Table 7-3 ALT Keys Keystroke 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M...
  • Page 125 USB Interface 7 - 19 USB GUI Key Character Set (Continued) Table 7-4 GUI Key Keystroke 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070...
  • Page 126 7 - 20 Symbol DS6707 Digital Imager Scanner Product Reference Guide USB GUI Key Character Set (Continued) Table 7-4 GUI Key Keystroke 3088 GUI X 3089 GUI Y 3090 GUI Z Note: GUI Shift Keys - The Apple™ iMac keyboard has an apple key on either side of the space bar.
  • Page 127 USB Interface 7 - 21 USB F Key Character Set (Continued) Table 7-5 F Keys Keystroke 5022 5023 5024 USB Numeric Keypad Character Set Table 7-6 Numeric Keypad Keystroke 6042 6043 6044 undefined 6045 6046 6047 6048 6049 6050 6051 6052 6053 6054...
  • Page 128 7 - 22 Symbol DS6707 Digital Imager Scanner Product Reference Guide USB Extended Keypad Character Set (Continued) Table 7-7 Extended Keypad Keystroke 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014...
  • Page 129: Chapter 8 Rs-232 Interface

    TTL RS-232 signal levels, which interface with most system architectures. NOTE For system architectures requiring RS-232C signal levels, Motorola offers different cables providing TTL-to-RS-232C conversion. Contact Motorola Enterprise Mobility Support for more information. Throughout the programming bar code menus, asterisks ( ) indicate default values.
  • Page 130: Connecting An Rs-232 Interface

    8 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Connecting an RS-232 Interface The digital imager scanner connects directly to the host computer. Interface Cable Serial Port Connector to Host Power Supply Cable RS-232 Direct Connection Figure 8-1 NOTE Interface cables vary depending on configuration.
  • Page 131: Rs-232 Parameter Defaults

    RS-232 Interface 8 - 3 RS-232 Parameter Defaults Table 8-1 lists the defaults for RS-232 host parameters. To change any option, scan the appropriate bar code(s) provided in the RS-232 Host Parameters section beginning on page 8-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
  • Page 132: Host Parameters

    8 - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide RS-232 Host Parameters Various RS-232 hosts use their own parameter default settings. Selecting standard, ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed in Table 8-2.
  • Page 133 RS-232 Interface 8 - 5 RS-232 Host Parameters (continued) Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron enables the transmission of code ID characters listed in Table 8-3. These code ID characters are not programmable and are separate from the Transmit Code ID feature.
  • Page 134: Host Types

    8 - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide RS-232 Host Types To select an RS-232 host interface, scan one of the following bar codes. Standard RS-232 ICL RS-232 Wincor-Nixdorf RS-232 Mode A Wincor-Nixdorf RS-232 Mode B Olivetti ORS4500 Omron Scanning Enable RS-232 (No Variant) activates the RS-232 driver, but does not change port settings (e.g., parity,...
  • Page 135: Baud Rate

    RS-232 Interface 8 - 7 RS-232 Host Types (continued) OPOS/JPOS Fujitsu RS-232 Baud Rate Baud rate is the number of bits of data transmitted per second. Set the digital imager scanner's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form.
  • Page 136 8 - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide Baud Rate (continued) Baud Rate 9600 Baud Rate 19,200 Baud Rate 38,400 Baud Rate 57,600 Baud Rate 115,200...
  • Page 137: Parity

    RS-232 Interface 8 - 9 Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. • Select Odd parity to set the parity bit value to 0 or 1, based on data, to ensure that the coded character contains an odd number of 1 bits •...
  • Page 138: Stop Bit Select

    8 - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. Select the number of stop bits (one or two) based on the number the receiving terminal is programmed to accommodate.
  • Page 139: Check Receive Errors

    RS-232 Interface 8 - 11 Check Receive Errors Select whether or not to check the parity, framing, and overrun of received characters. The parity value of received characters is verified against the parity parameter selected above. Check For Received Errors Do Not Check For Received Errors Hardware Handshaking The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking...
  • Page 140 8 - 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide Hardware Handshaking (continued) • None: Scan this bar code to disable hardware handshaking. • Standard RTS/CTS: Scan this bar code to select Standard RTS/CTS Hardware Handshaking. • RTS/CTS Option 1: If you select RTS/CTS Option 1, the digital imager scanner asserts RTS before transmitting and ignores the state of CTS.
  • Page 141: Software Handshaking

    RS-232 Interface 8 - 13 Hardware Handshaking (continued) RTS/CTS Option 2 RTS/CTS Option 3 Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options. If software handshaking and hardware handshaking are both enabled, hardware handshaking takes precedence.
  • Page 142 8 - 14 Symbol DS6707 Digital Imager Scanner Product Reference Guide Software Handshaking (continued) • XON/XOFF: An XOFF character turns the digital imager scanner transmission off until the digital imager scanner receives an XON character. There are two situations for XON/XOFF: •...
  • Page 143: Host Serial Response Time-Out

    RS-232 Interface 8 - 15 Host Serial Response Time-out This parameter specifies how long the digital imager scanner waits for an ACK, NAK, or CTS before determining that a transmission error occurred. This only applies when in one of the ACK/NAK software handshaking modes, or RTS/CTS hardware handshaking mode.
  • Page 144: Rts Line State

    8 - 16 Symbol DS6707 Digital Imager Scanner Product Reference Guide RTS Line State This parameter sets the idle state of the Serial Host RTS line. Scan a bar code below to select Low RTS or High RTS line state.
  • Page 145: Intercharacter Delay

    RS-232 Interface 8 - 17 Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions. Minimum: 0 msec Low: 25 msec Medium: 50 msec High: 75 msec Maximum: 99 msec...
  • Page 146: Nixdorf Beep/Led Options

    8 - 18 Symbol DS6707 Digital Imager Scanner Product Reference Guide Nixdorf Beep/LED Options If you selected Nixdorf Mode B, this indicates when the digital imager scanner beeps and turns on its LED after a decode. Normal Operation (Beep/LED immediately after decode)
  • Page 147: Ascii Character Set For Rs-232

    RS-232 Interface 8 - 19 ASCII Character Set for RS-232 You can assign the values in Table 8-4 as prefixes or suffixes for ASCII character data transmission. Prefix/Suffix Values Table 8-4 Prefix/Suffix Full ASCII ASCII Character Value Code 39 Encode Character 1000 1001 1002...
  • Page 148 8 - 20 Symbol DS6707 Digital Imager Scanner Product Reference Guide Prefix/Suffix Values (Continued) Table 8-4 Prefix/Suffix Full ASCII ASCII Character Value Code 39 Encode Character 1027 1028 1029 1030 1031 1032 Space Space 1033 1034 " 1035 1036 1037 1038 &...
  • Page 149 RS-232 Interface 8 - 21 Prefix/Suffix Values (Continued) Table 8-4 Prefix/Suffix Full ASCII ASCII Character Value Code 39 Encode Character 1057 1058 1059 1060 < 1061 1062 > 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077...
  • Page 150 8 - 22 Symbol DS6707 Digital Imager Scanner Product Reference Guide Prefix/Suffix Values (Continued) Table 8-4 Prefix/Suffix Full ASCII ASCII Character Value Code 39 Encode Character 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100...
  • Page 151 RS-232 Interface 8 - 23 Prefix/Suffix Values (Continued) Table 8-4 Prefix/Suffix Full ASCII ASCII Character Value Code 39 Encode Character 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 Undefined 7013 ENTER...
  • Page 152 8 - 24 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 153: Chapter 9 123Scan

    Chapter 9 123Scan Introduction 123Scan is a Windows ® -based utility that programs the digital imager scanner with all parameters including Advanced Data Formatting (ADF) rules. An ADF rule modifies bar code data before sending it to the host to ensure compatibility between bar coded data and the host application.
  • Page 154 9 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 155: Chapter 10 Symbologies

    Chapter 10 Symbologies Introduction This chapter describes symbology features and provides programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when you power down the digital imager scanner.
  • Page 156: Errors While Scanning

    10 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter. Symbology Parameter Defaults Table 10-1 lists the defaults for all symbologies parameters. There are two ways to change the default values: •...
  • Page 157 Symbologies 10 - 3 Parameter Defaults (Continued) Table 10-1 Parameter Page Parameter Default Number Number UPC-E1 Preamble System Character 10-18 Convert UPC-E to A Disable 10-19 Convert UPC-E1 to A Disable 10-19 EAN-8/JAN-8 Extend Disable 10-20 Bookland ISBN Format F1h 40h ISBN-10 10-21 UCC Coupon Extended Code...
  • Page 158 10 - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide Parameter Defaults (Continued) Table 10-1 Parameter Page Parameter Default Number Number Interleaved 2 of 5 (ITF) Interleaved 2 of 5 (ITF) Enable 10-40 Set Lengths for I 2 of 5...
  • Page 159 Symbologies 10 - 5 Parameter Defaults (Continued) Table 10-1 Parameter Page Parameter Default Number Number 4State Postal F1h 50h Disable 10-56 Post US4 F1h 63h Disable 10-57 Transmit US Postal Check Digit Enable 10-57 GS1 DataBar GS1 DataBar-14 F0h 52h Enable 10-58 GS1 DataBar Limited...
  • Page 160 10 - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide Parameter Defaults (Continued) Table 10-1 Parameter Page Parameter Default Number Number Symbology-Specific Security Levels Redundancy Level 10-73 Security Level 10-75 Intercharacter Gap Size F0h 7Dh Normal 10-76 Report Version...
  • Page 161: Upc/Ean

    Symbologies 10 - 7 UPC/EAN Enable/Disable UPC-A Parameter # 01h To enable or disable UPC-A, scan the appropriate bar code below Enable UPC-A (01h) Disable UPC-A (00h) Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, scan the appropriate bar code below Enable UPC-E (01h) Disable UPC-E...
  • Page 162: Enable/Disable Upc-E1

    10 - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. NOTE UPC-E1 is not a UCC (Uniform Code Council) approved symbology.
  • Page 163: Enable/Disable Bookland Ean

    Symbologies 10 - 9 Enable/Disable EAN-13/JAN-13 Parameter # 03h To enable or disable EAN-13/JAN-13, scan the appropriate bar code below. Enable EAN-13/JAN-13 (01h) Disable EAN-13/JAN-13 (00h) Enable/Disable Bookland EAN Parameter # 53h To enable or disable Bookland EAN, scan the appropriate bar code below. Enable Bookland EAN (01h) Disable Bookland EAN...
  • Page 164: Decode Upc/Ean/Jan Supplementals

    10 - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide Decode UPC/EAN/JAN Supplementals Parameter # 10h Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). The following options are available: •...
  • Page 165 Symbologies 10 - 11 Decode UPC/EAN/JAN Supplementals (continued) Decode UPC/EAN/JAN Only With Supplementals (01h) Ignore Supplementals (00h) Autodiscriminate UPC/EAN/JAN Supplementals (02h) Enable 378/379 Supplemental Mode (04h) Enable 978/979 Supplemental Mode (05h) Enable 977 Supplemental Mode (07h)
  • Page 166 10 - 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide Decode UPC/EAN/JAN Supplementals (continued) 414/419/434/439 Supplemental Mode Enable (06h) 491 Supplemental Mode Enable (08h) Enable Smart Supplemental Mode (03h) Supplemental User-Programmable Type 1 (09h) Supplemental User-Programmable Type 1 and 2...
  • Page 167: User-Programmable Supplementals

    Symbologies 10 - 13 User-Programmable Supplementals Supplemental 1: Parameter # F1h 43h Supplemental 2: Parameter # F1h 44h If you selected a Supplemental User-Programmable option from Decode UPC/EAN/JAN Supplementals on page 10-10, select User-Programmable Supplemental 1 to set the 3-digit prefix. Then select the 3 digits using the numeric bar codes beginning on page D-1.
  • Page 168: Upc/Ean/Jan Supplemental Redundancy

    10 - 14 Symbol DS6707 Digital Imager Scanner Product Reference Guide UPC/EAN/JAN Supplemental Redundancy Parameter # 50h If you selected Autodiscriminate UPC/EAN/JAN Supplementals, this option adjusts the number of times a symbol without supplementals is decoded before transmission. The range is from two to thirty times. Five or above is recommended when decoding a mix of UPC/EAN/JAN symbols with and without supplementals.
  • Page 169: Transmit Upc-E Check Digit

    Symbologies 10 - 15 Transmit UPC-E Check Digit Parameter # 29h The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E check digit. It is always verified to guarantee the integrity of the data.
  • Page 170 10 - 16 Symbol DS6707 Digital Imager Scanner Product Reference Guide UPC-A Preamble Parameter # 22h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-A preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0”...
  • Page 171 Symbologies 10 - 17 UPC-E Preamble Parameter # 23h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0”...
  • Page 172: Upc-E1 Preamble

    10 - 18 Symbol DS6707 Digital Imager Scanner Product Reference Guide UPC-E1 Preamble Parameter # 24h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E1 preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0”...
  • Page 173: Convert Upc-E1 To Upc-A

    Symbologies 10 - 19 Convert UPC-E to UPC-A Parameter # 25h Enable this to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
  • Page 174: Ean-8/Jan-8 Extend

    10 - 20 Symbol DS6707 Digital Imager Scanner Product Reference Guide EAN-8/JAN-8 Extend Parameter # 27h Enable this to add five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. Disable this to transmit EAN-8 symbols as is.
  • Page 175: Bookland Isbn Format

    Symbologies 10 - 21 Bookland ISBN Format Parameter # F1h 40h If you enabled Bookland EAN using Enable/Disable Bookland EAN on page 10-9, select one of the following formats for Bookland data: • Bookland ISBN-10 - The scanner reports Bookland data starting with 978 in traditional 10-digit format with the special Bookland check digit for backward-compatibility.
  • Page 176: Ucc Coupon Extended Code

    10 - 22 Symbol DS6707 Digital Imager Scanner Product Reference Guide UCC Coupon Extended Code Parameter # 55h Enable this to decode UPC-A bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPC-A/EAN-128 Coupon Codes. UPCA, EAN-13, and EAN-128 must be enabled to scan all types of Coupon Codes.
  • Page 177: Code 128

    Symbologies 10 - 23 Code 128 Enable/Disable Code 128 Parameter # 08h To enable or disable Code 128, scan the appropriate bar code below. Enable Code 128 (01h) Disable Code 128 (00h) Set Lengths for Code 128 Parameter # L1 = D1h, L2 = D2h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
  • Page 178: Set Lengths For Code 128

    10 - 24 Symbol DS6707 Digital Imager Scanner Product Reference Guide Set Lengths for Code 128 (continued) Code 128 - One Discrete Length Code 128 - Two Discrete Lengths Code 128 - Length Within Range *Code 128 - Any Length...
  • Page 179: Enable/Disable Gs1-128 (Formerly Ucc/Ean-128)

    Symbologies 10 - 25 Enable/Disable GS1-128 (formerly UCC/EAN-128) Parameter # 0Eh To enable or disable GS1-128, scan the appropriate bar code below. Enable GS1-128 (01h) Disable GS1-128 (00h) Enable/Disable ISBT 128 Parameter # 54h ISBT 128 is a variant of Code 128 used in the blood bank industry. Scan a bar code below to enable or disable ISBT 128.
  • Page 180: Code 39

    10 - 26 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code 39 Enable/Disable Code 39 Parameter # 00h To enable or disable Code 39, scan the appropriate bar code below. Enable Code 39 (01h) Disable Code 39 (00h) Enable/Disable Trioptic Code 39 Parameter # 0Dh Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges.
  • Page 181: Convert Code 39 To Code 32

    Symbologies 10 - 27 Convert Code 39 to Code 32 Parameter # 56h Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. NOTE Code 39 must be enabled for this parameter to function.
  • Page 182: Set Lengths For Code 39

    10 - 28 Symbol DS6707 Digital Imager Scanner Product Reference Guide Set Lengths for Code 39 Parameter # L1 = 12h, L2 = 13h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
  • Page 183: Code 39 Check Digit Verification

    Symbologies 10 - 29 Set Lengths for Code 39 (continued) Code 39 - Length Within Range Code 39 - Any Length Code 39 Check Digit Verification Parameter # 30h Enable this feature to check the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm.
  • Page 184: Transmit Code 39 Check Digit

    10 - 30 Symbol DS6707 Digital Imager Scanner Product Reference Guide Transmit Code 39 Check Digit Parameter # 2Bh Scan a bar code below to transmit Code 39 data with or without the check digit. Transmit Code 39 Check Digit (Enable)
  • Page 185: Code 39 Buffering (Scan & Store)

    Select Do Not Buffer Code 39 to transmit all decoded Code 39 symbols immediately without being stored in the buffer. This feature affects Code 39 only. If selecting Buffer Code 39, Motorola recommends configuring the digital imager scanner to decode Code 39 symbology only.
  • Page 186 10 - 32 Symbol DS6707 Digital Imager Scanner Product Reference Guide Clear Transmission Buffer To clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character, a dash (minus), and a stop character. •...
  • Page 187 Symbologies 10 - 33 Overfilling Transmission Buffer The Code 39 buffer holds 200 characters. If the symbol just read results in an overflow of the transmission buffer: • The digital imager scanner indicates that it rejected the symbol by issuing three long, high beeps. •...
  • Page 188: Code 93

    10 - 34 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code 93 Enable/Disable Code 93 Parameter # 09h To enable or disable Code 93, scan the appropriate bar code below. Enable Code 93 (01h) Disable Code 93 (00h) Set Lengths for Code 93 Parameter # L1 = 1Ah, L2 = 1Bh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s)
  • Page 189: Set Lengths For Code 93

    Symbologies 10 - 35 Set Lengths for Code 93 (continued) Code 93 - One Discrete Length Code 93 - Two Discrete Lengths Code 93 - Length Within Range Code 93 - Any Length...
  • Page 190: Code 11

    10 - 36 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code 11 Code 11 Parameter # 0Ah To enable or disable Code 11, scan the appropriate bar code below. Enable Code 11 (01h) Disable Code 11 (00h) Set Lengths for Code 11 Parameter # L1 = 1Ch, L2 = 1Dh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s)
  • Page 191 Symbologies 10 - 37 Set Lengths for Code 11 (continued) Code 11 - One Discrete Length Code 11 - Two Discrete Lengths Code 11 - Length Within Range Code 11 - Any Length...
  • Page 192: Code 11 Check Digit Verification

    10 - 38 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code 11 Check Digit Verification Parameter # 34h Enable this to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm.
  • Page 193: Transmit Code 11 Check Digits

    Symbologies 10 - 39 Transmit Code 11 Check Digits Parameter # 2Fh This feature selects whether or not to transmit the Code 11 check digit(s). Transmit Code 11 Check Digit(s) (Enable) (01h) Do Not Transmit Code 11 Check Digit(s) (Disable) (00h) NOTE Code 11 Check Digit Verification must be enabled for this parameter to function.
  • Page 194: Interleaved 2 Of 5 (Itf)

    10 - 40 Symbol DS6707 Digital Imager Scanner Product Reference Guide Interleaved 2 of 5 (ITF) Enable/Disable Interleaved 2 of 5 Parameter # 06h To enable or disable Interleaved 2 of 5, scan the appropriate bar code below, and select an Interleaved 2 of 5 length from the following pages.
  • Page 195 Symbologies 10 - 41 Set Lengths for Interleaved 2 of 5 I 2 of 5 - One Discrete Length I 2 of 5 - Two Discrete Lengths I 2 of 5 - Length Within Range I 2 of 5 - Any Length...
  • Page 196: I 2 Of 5 Check Digit Verification

    10 - 42 Symbol DS6707 Digital Imager Scanner Product Reference Guide I 2 of 5 Check Digit Verification Parameter # 31h Enable this to check the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification (USS), or the Optical Product Code Council (OPCC) check digit algorithm.
  • Page 197: Convert I 2 Of 5 To Ean-13

    Symbologies 10 - 43 Convert I 2 of 5 to EAN-13 Parameter # 52h Enable this parameter to convert 14-character I 2 of 5 codes to EAN-13, and transmit to the host as EAN-13. To accomplish this, the I 2 of 5 code must be enabled, and the code must have a leading zero and a valid EAN-13 check digit.
  • Page 198: Discrete 2 Of 5 (Dtf)

    10 - 44 Symbol DS6707 Digital Imager Scanner Product Reference Guide Discrete 2 of 5 (DTF) Enable/Disable Discrete 2 of 5 Parameter # 05h To enable or disable Discrete 2 of 5, scan the appropriate bar code below. Enable Discrete 2 of 5...
  • Page 199: Set Lengths For Discrete 2 Of 5

    Symbologies 10 - 45 Set Lengths for Discrete 2 of 5 (continued) D 2 of 5 - One Discrete Length D 2 of 5 - Two Discrete Lengths D 2 of 5 - Length Within Range D 2 of 5 - Any Length...
  • Page 200: Codabar (Nw - 7)

    10 - 46 Symbol DS6707 Digital Imager Scanner Product Reference Guide Codabar (NW - 7) Enable/Disable Codabar Parameter # 07h To enable or disable Codabar, scan the appropriate bar code below. Enable Codabar (01h) Disable Codabar (00h) Set Lengths for Codabar Parameter # L1 = 18h, L2 = 19h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s)
  • Page 201 Symbologies 10 - 47 Set Lengths for Codabar (continued) Codabar - One Discrete Length Codabar - Two Discrete Lengths Codabar - Length Within Range Codabar - Any Length...
  • Page 202: Clsi Editing

    10 - 48 Symbol DS6707 Digital Imager Scanner Product Reference Guide CLSI Editing Parameter # 36h Enable this to strip the start and stop characters and insert a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format.
  • Page 203: Msi

    Symbologies 10 - 49 Enable/Disable MSI Parameter # 0Bh To enable or disable MSI, scan the appropriate bar code below. Enable MSI (01h) Disable MSI (00h) Set Lengths for MSI Parameter # L1 = 1Eh, L2 = 1Fh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
  • Page 204: Msi Check Digits

    10 - 50 Symbol DS6707 Digital Imager Scanner Product Reference Guide Set Lengths for MSI (continued) MSI - One Discrete Length MSI - Two Discrete Lengths MSI - Length Within Range MSI - Any Length MSI Check Digits Parameter # 32h With MSI symbols, one check digit is mandatory and always verified by the reader.
  • Page 205: Transmit Msi Check Digit(S)

    Symbologies 10 - 51 Transmit MSI Check Digit(s) Parameter # 2Eh Scan a bar code below to transmit MSI data with or without the check digit. Transmit MSI Check Digit(s) (Enable) (01h Do Not Transmit MSI Check Digit(s) (Disable) (00h) MSI Check Digit Algorithm Parameter # 33h Two algorithms are possible for verifying the second MSI check digit.
  • Page 206: Inverse 1D

    10 - 52 Symbol DS6707 Digital Imager Scanner Product Reference Guide Inverse 1D Parameter # F1h 4Ah This parameter sets the 1D inverse decoder setting. Options are: • - the scanner decodes regular 1D bar codes only. Regular Only •...
  • Page 207: Postal Codes

    Symbologies 10 - 53 Postal Codes US Postnet Parameter # 59h To enable or disable US Postnet, scan the appropriate bar code below. Enable US Postnet (01h) Disable US Postnet (00h) US Planet Parameter # 5Ah To enable or disable US Planet, scan the appropriate bar code below. Enable US Planet (01h) Disable US Planet...
  • Page 208: Uk Postal

    10 - 54 Symbol DS6707 Digital Imager Scanner Product Reference Guide UK Postal Parameter # 5Bh To enable or disable UK Postal, scan the appropriate bar code below. Enable UK Postal (01h) Disable UK Postal (00h) Transmit UK Postal Check Digit Parameter # 60h Select whether to transmit UK Postal data with or without the check digit.
  • Page 209: Japan Postal

    Symbologies 10 - 55 Japan Postal Parameter # F0h, 22h To enable or disable Japan Postal, scan the appropriate bar code below. Enable Japan Postal (01h) Disable Japan Postal (00h) Australian Postal Parameter # F0h, 23h To enable or disable Australian Postal, scan the appropriate bar code below. Enable Australian Postal (01h) Disable Australian Postal...
  • Page 210: Dutch Postal

    10 - 56 Symbol DS6707 Digital Imager Scanner Product Reference Guide Dutch Postal Parameter # F0h, 46h To enable or disable Dutch Postal, scan the appropriate bar code below. Enable Dutch Postal (01h) Disable Dutch Postal (00h) 4State Postal Parameter # F1h 50h To enable or disable 4State Postal, scan the appropriate bar code below.
  • Page 211: Post Us4

    Symbologies 10 - 57 Post US4 Parameter # F1h 63h To enable or disable Post US4, scan the appropriate bar code below. Enable Post US4 (01h) Disable Post US4 (00h) Transmit US Postal Check Digit Parameter # 5Fh Select whether to transmit US Postal data with or without the check digit. Transmit US Postal Check Digit (01h) Do Not Transmit US Postal Check Digit...
  • Page 212: Gs1 Databar

    10 - 58 Symbol DS6707 Digital Imager Scanner Product Reference Guide GS1 DataBar The variants of GS1 DataBar are DataBar-14, DataBar Expanded, and DataBar Limited. The limited and expanded versions have stacked variants. Scan the appropriate bar codes to enable or disable each variant of GS1 DataBar.
  • Page 213: Gs1 Databar Expanded

    Symbologies 10 - 59 GS1 DataBar Expanded Parameter # F0h 54h. Enable GS1 DataBar Expanded (01h) Disable GS1 DataBar Expanded (00h) Convert GS1 DataBar to UPC/EAN Parameter # F0h, 8Dh This parameter only applies to DataBar-14 and DataBar Limited symbols not decoded as part of a Composite symbol.
  • Page 214: Composite

    10 - 60 Symbol DS6707 Digital Imager Scanner Product Reference Guide Composite Composite CC-C Parameter # F0h 55h Scan a bar code below to enable or disable Composite bar codes of type CC-C. Enable CC-C (01h) Disable CC-C (00h) Composite CC-A/B Parameter # F0h 56h Scan a bar code below to enable or disable Composite bar codes of type CC-A/B.
  • Page 215: Composite Tlc-39

    Symbologies 10 - 61 Composite TLC-39 Parameter # F0h 73h Scan a bar code below to enable or disable Composite bar codes of type TLC-39. Enable TLC39 (01h) Disable TLC39 (00h)
  • Page 216: Upc Composite Mode

    10 - 62 Symbol DS6707 Digital Imager Scanner Product Reference Guide UPC Composite Mode Parameter # F0h 58h Select one of three options for “linking” UPC symbols with a 2D symbol during transmission as if they were one symbol: •...
  • Page 217: Composite Beep Mode

    Symbologies 10 - 63 Composite Beep Mode Parameter # F0h, 8Eh To select the number of decode beeps when a the scanner decodes a composite bar code, scan the appropriate bar code. Single Beep after both are decoded (00h) Beep as each code type is decoded (01h) Double Beep after both are decoded (02h)
  • Page 218: 2D Symbologies

    10 - 64 Symbol DS6707 Digital Imager Scanner Product Reference Guide 2D Symbologies Enable/Disable PDF417 Parameter # 0Fh To enable or disable PDF417, scan the appropriate bar code below. Enable PDF417 (01h) Disable PDF417 (00h) Enable/Disable MicroPDF417 Parameter # E3h To enable or disable MicroPDF417, scan the appropriate bar code below.
  • Page 219: Code 128 Emulation

    Symbologies 10 - 65 Code 128 Emulation Parameter # 7Bh Enable this parameter to transmit data from certain MicroPDF417 symbols as if it was encoded in Code 128 symbols. You must select AIM Code ID Character (01h) on page 4-15 for this parameter to work.
  • Page 220: Data Matrix

    10 - 66 Symbol DS6707 Digital Imager Scanner Product Reference Guide Data Matrix Parameter # F0h, 24h To enable or disable Data Matrix, scan the appropriate bar code below. Enable Data Matrix (01h) Disable Data Matrix (00h)
  • Page 221: Data Matrix Inverse

    Symbologies 10 - 67 Data Matrix Inverse Parameter # F1h 4Ch This parameter sets the Data Matrix inverse decoder setting. Options are: • - the scanner decodes regular Data Matrix bar codes only. Regular Only • - the scanner decodes inverse Data Matrix bar codes only. Inverse Only •...
  • Page 222: Maxicode

    10 - 68 Symbol DS6707 Digital Imager Scanner Product Reference Guide Maxicode Parameter # F0h, 26h To enable or disable Maxicode, scan the appropriate bar code below. Enable Maxicode (01h) Disable Maxicode (00h) QR Code Parameter # F0h,25h To enable or disable QR Code, scan the appropriate bar code below.
  • Page 223: Microqr

    Symbologies 10 - 69 MicroQR Parameter # F1h 3Dh To enable or disable MicroQR, scan the appropriate bar code below. Enable MicroQR (01h) Disable MicroQR (00h)
  • Page 224: Qr Inverse

    10 - 70 Symbol DS6707 Digital Imager Scanner Product Reference Guide QR Inverse Parameter # F1h 4Bh This parameter sets the QR inverse decoder setting. Options are: • - the scanner decodes regular QR bar codes only. Regular Only •...
  • Page 225: Aztec

    Symbologies 10 - 71 Aztec Parameter # F1h 3Eh To enable or disable Aztec, scan the appropriate bar code below. Enable Aztec (01h) Disable Aztec (00h)
  • Page 226: Aztec Inverse

    10 - 72 Symbol DS6707 Digital Imager Scanner Product Reference Guide Aztec Inverse Parameter # F1h 4Dh This parameter sets the Aztec inverse decoder setting. Options are: • - the scanner decodes regular Aztec bar codes only. Regular Only •...
  • Page 227: Redundancy Level 1

    Symbologies 10 - 73 Redundancy Level Parameter # 4Eh The digital imager scanner offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the digital imager scanner’s aggressiveness decreases. Select the redundancy level appropriate for the bar code quality.
  • Page 228: Redundancy Level 4

    10 - 74 Symbol DS6707 Digital Imager Scanner Product Reference Guide Redundancy Level (continued) Redundancy Level 4 The following code types must be successfully read three times before being decoded: Redundancy Level 4 Codes Table 10-5 Code Type Code Length...
  • Page 229: Security Level

    Symbologies 10 - 75 Security Level Parameter # 4Dh The digital imager scanner offers four levels of decode security for delta bar codes, which include the Code 128 family, UPC/EAN, and Code 93. Select increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship between security and digital imager scanner aggressiveness, so choose only that level of security necessary for any given application.
  • Page 230: Intercharacter Gap Size

    10 - 76 Symbol DS6707 Digital Imager Scanner Product Reference Guide Intercharacter Gap Size Parameter # F0h, 7Dh The Code 39 and Codabar symbologies have an intercharacter gap that is typically quite small. Due to various bar code-printing technologies, this gap can grow larger than the maximum size allowed, preventing the digital imager scanner from decoding the symbol.
  • Page 231: Macro Pdf Features

    Symbologies 10 - 77 Macro PDF Features Macro PDF is a special feature for concatenating multiple PDF symbols into one file. The digital imager scanner can decode symbols that are encoded with this feature, and can store more than 64 kB of decoded data stored in up to 50 MacroPDF symbols.
  • Page 232 10 - 78 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 233: Chapter 11 Advanced Data Formatting

    Chapter 11 Advanced Data Formatting Introduction Advanced Data Formatting (ADF) is a means of customizing data before transmission to the host device. Use ADF to edit scan data to suit requirements. Implement ADF by scanning a related series of bar codes, which begin on page 11-8, or by installing the 123Scan utility (see...
  • Page 234: Using Adf Bar Codes

    11 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Using ADF Bar Codes When programming a rule, make sure the rule is logically correct. Plan ahead before scanning. To program each data formatting rule: • Start the Rule. Scan the Begin New Rule bar code on page 11-8.
  • Page 235: Rule 1: The Code 128 Scanning Rule

    Advanced Data Formatting 11 - 3 Rule 1: The Code 128 Scanning Rule Step Bar Code On Page Beep Indication Begin New Rule 11-8 High High Code 128 11-11 High High Send next 5 characters 11-28 High High Send <CTRL M> 11-48 High High Send next 5 characters...
  • Page 236: Rules Hierarchy (In Bar Codes)

    11 - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide and the cashier keys the price manually. To implement this, first enter an ADF rule that applies to the normal situation, such as: Scan Rule Belongs to Set 1. When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key, send the data that remains, send the Enter key.
  • Page 237: Default Rules

    Advanced Data Formatting 11 - 5 Note that using the standard data editing functions also creates ADF rules. Scan options are entered as ADF rules, and the previous hierarchy also applies to them. For the digital imager scanner, this applies to prefix/suffix programming in the parameter Scan Data Transmission Format on page 4-17.
  • Page 238 11 - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide ADF Bar Codes (Continued) Table 11-1 Page Parameter Number Numeric Keypad 11-24 Rule Belongs To Set 11-26 Actions 11-27 Send Data 11-27 Send Data Up To Character 11-27 Send Next Character...
  • Page 239 Advanced Data Formatting 11 - 7 ADF Bar Codes (Continued) Table 11-1 Page Parameter Number Send Right Control Key 11-82 Send Graphic User Interface (GUI) Characters 11-83 Send GUI 0 Send GUI 9 11-83 Send GUI A Send GUI Z 11-84 Turn On/Off Rule Sets 11-88...
  • Page 240: Special Commands

    11 - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide Special Commands Pause Duration This parameter, along with the Send Pause parameter on page 11-31, inserts a pause in the data transmission. Set the pause by scanning a two-digit number (i.e., two bar codes) representing a 0.1 second interval. For example, scan bar codes 0 and 1 to insert a 0.1 second pause;...
  • Page 241: Erase

    Advanced Data Formatting 11 - 9 Erase Use these bar codes to erase criteria, actions, or rules. Erase Criteria And Start Again Erase Actions And Start Again Erase Previously Saved Rule Erase All Rules Quit Entering Rules Scan the bar code below to quit entering rules. Quit Entering Rules...
  • Page 242: Disable Rule Set

    11 - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide Disable Rule Set Use these bar codes to disable rule sets. Disable Rule Set 1 Disable Rule Set 2 Disable Rule Set 3 Disable Rule Set 4 Disable All Rule Sets...
  • Page 243: Criteria

    Advanced Data Formatting 11 - 11 Criteria Code Types Select all code types to be affected by the rule. Scan all selected codes in succession, before selecting other criteria. To select all code types, do not scan any code type. Code 39 Codabar GS1 DataBar-14...
  • Page 244 11 - 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Types (continued) IATA 2 OF 5 I 2 OF 5 Code 93 UPC-A UPC-E EAN-8 EAN-13...
  • Page 245 Advanced Data Formatting 11 - 13 Code Types (continued) GS1-128 UPC-E1 Bookland EAN Trioptic Code 39 Code 11 Code 32...
  • Page 246 11 - 14 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Types (continued) ISBT 128 Coupon Code US Postnet US Planet UK Postal Japan Postal Australian Postal...
  • Page 247 Advanced Data Formatting 11 - 15 Code Types (continued) Dutch Postal 4State Postal Post US4 PDF417 MicroPDF Macro PDF Macro MicroPDF...
  • Page 248 11 - 16 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Types (continued) MaxiCode Data Matrix QR Code MicroQR TLC 39 UPC/EAN Composites GS1 DataBar and EAN128 Composites...
  • Page 249 Advanced Data Formatting 11 - 17 Code Types (continued) Aztec Aztec Rune NOTE When selecting composite bar codes, enable AIM IDs if parsing UPC or EAN composite data, or data from an application that uses symbol separators.
  • Page 250: Code Lengths

    11 - 18 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Lengths Scan these bar codes to define the number of characters the selected code type must contain. Select one length per rule only. Do not select any code length to select code types of any length.
  • Page 251 Advanced Data Formatting 11 - 19 Code Lengths (continued) 7 Characters 8 Characters 9 Characters 10 Characters 11 Characters 12 Characters 13 Characters...
  • Page 252 11 - 20 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Lengths (continued) 14 Characters 15 Characters 16 Characters 17 Characters 18 Characters 19 Characters 20 Characters...
  • Page 253 Advanced Data Formatting 11 - 21 Code Lengths (continued) 21 Characters 22 Characters 23 Characters 24 Characters 25 Characters 26 Characters 27 Characters...
  • Page 254 11 - 22 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Lengths (continued) 28 Characters 29 Characters 30 Characters...
  • Page 255: Message Containing A Specific Data String

    Advanced Data Formatting 11 - 23 Message Containing A Specific Data String Use this feature to select whether the formatting affects data that begins with a specific character or data string, or contains a specific character or data string. There are 5 features: •...
  • Page 256: Numeric Keypad

    11 - 24 Symbol DS6707 Digital Imager Scanner Product Reference Guide Numeric Keypad Do not confuse bar codes on this page with those on the alphanumeric keyboard.
  • Page 257 Advanced Data Formatting 11 - 25 Numeric Keypad (continued) Cancel...
  • Page 258 11 - 26 Symbol DS6707 Digital Imager Scanner Product Reference Guide Rule Belongs To Set Select the set to which a rule belongs. There are four possible rule sets. See Alternate Rule Sets on page 11-3 more information about rule sets.
  • Page 259: Actions

    Advanced Data Formatting 11 - 27 Actions Select how to format the data for transmission. Send Data Send all data that follows, send all data up to a specific character selected from the Alphanumeric Keyboard on page 11-90, or send the next X characters. Note that only bar codes for Send Next 1 to 20 appear here, and can be scanned multiple times to send values greater then 20.
  • Page 260 11 - 28 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Data (continued) Send Next 5 Characters Send Next 6 Characters Send Next 7 Characters Send Next 8 Characters Send Next 9 Characters Send Next 10 Characters Send Next 11 Characters...
  • Page 261 Advanced Data Formatting 11 - 29 Send Data (continued) Send Next 12 Characters Send Next 13 Characters Send Next 14 Characters Send Next 15 Characters Send Next 16 Characters Send Next 17 Characters Send Next 18 Characters...
  • Page 262: Setup Field(S)

    11 - 30 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Data (continued) Send Next 19 Characters Send Next 20 Characters Setup Field(s) Setup Field(s) Definitions Table 11-2 Parameter Description Page Move Cursor Move Cursor To a Character Scan...
  • Page 263: Move Cursor

    Advanced Data Formatting 11 - 31 Move Cursor Scan a bar code below to move the cursor in relation to a specified character. Then enter a character by scanning a bar code from the Alphanumeric Keyboard on page 11-90. NOTE If there is no match and the rule fails, the next rule is checked. Move Cursor To Character Move Cursor To Start Move Cursor Past Character...
  • Page 264: Skip Ahead

    11 - 32 Symbol DS6707 Digital Imager Scanner Product Reference Guide Skip Ahead Use the following bar codes to skip ahead characters. Skip Ahead 1 Character Skip Ahead 2 Characters Skip Ahead 3 Characters Skip Ahead 4 Characters Skip Ahead 5 Characters...
  • Page 265: Skip Back

    Advanced Data Formatting 11 - 33 Skip Ahead (continued) Skip Ahead 8 Characters Skip Ahead 9 Characters Skip Ahead 10 Characters Skip Back Use the following bar codes to skip back characters. Skip Back 1 Character Skip Back 2 Characters Skip Back 3 Characters...
  • Page 266 11 - 34 Symbol DS6707 Digital Imager Scanner Product Reference Guide Skip Back (continued) Skip Back 4 Characters Skip Back 5 Characters Skip Back 6 Characters Skip Back 7 Characters Skip Back 8 Characters Skip Back 9 Characters Skip Back 10 Characters...
  • Page 267: Send Preset Value

    Advanced Data Formatting 11 - 35 Send Preset Value Use these bar codes to send preset values. Set these values using the Scan Prefix and Scan Suffix bar codes on page 4-16. Send Prefix Send Suffix...
  • Page 268: Modify Data

    11 - 36 Symbol DS6707 Digital Imager Scanner Product Reference Guide Modify Data Modify data as described below. The following actions work for all send commands that follow it within a rule. Programming pad zeros to length 6, send next 3 characters, stop padding, send next 5 characters, adds three zeros to the first send, and the next send is unaffected by the padding.
  • Page 269: Pad Data With Spaces

    Advanced Data Formatting 11 - 37 Pad Data with Spaces To pad data to the left, scan the bar code containing the desired number of spaces. Send commands activate this parameter. Pad Spaces To Length 1 Pad Spaces To Length 2 Pad Spaces To Length 3 Pad Spaces To Length 4 Pad Spaces To Length 5...
  • Page 270 11 - 38 Symbol DS6707 Digital Imager Scanner Product Reference Guide Pad Data with Spaces (continued) Pad Spaces To Length 8 Pad Spaces To Length 9 Pad Spaces To Length 10 Pad Spaces To Length 11 Pad Spaces To Length 12...
  • Page 271 Advanced Data Formatting 11 - 39 Pad Data with Spaces (continued) Pad Spaces To Length 15 Pad Spaces To Length 16 Pad Spaces To Length 17 Pad Spaces To Length 18 Pad Spaces To Length 19 Pad Spaces To Length 20 Pad Spaces To Length 21...
  • Page 272 11 - 40 Symbol DS6707 Digital Imager Scanner Product Reference Guide Pad Data with Spaces (continued) Pad Spaces To Length 22 Pad Spaces To Length 23 Pad Spaces To Length 24 Pad Spaces To Length 25 Pad Spaces To Length 26...
  • Page 273: Pad Data With Zeros

    Advanced Data Formatting 11 - 41 Pad Data with Spaces (continued) Pad Spaces To Length 29 Pad Spaces To Length 30 Stop Pad Spaces Pad Data with Zeros To pad data to the left, scan the bar code containing the desired number of zeros. Send commands activate this parameter.
  • Page 274 11 - 42 Symbol DS6707 Digital Imager Scanner Product Reference Guide Pad Data with Zeros (continued) Pad Zeros To Length 4 Pad Zeros To Length 5 Pad Zeros To Length 6 Pad Zeros To Length 7 Pad Zeros To Length 8...
  • Page 275 Advanced Data Formatting 11 - 43 Pad Data with Zeros (continued) Pad Zeros To Length 11 Pad Zeros To Length 12 Pad Zeros To Length 13 Pad Zeros To Length 14 Pad Zeros To Length 15 Pad Zeros To Length 16 Pad Zeros To Length 17...
  • Page 276 11 - 44 Symbol DS6707 Digital Imager Scanner Product Reference Guide Pad Data with Zeros (continued) Pad Zeros To Length 18 Pad Zeros To Length 19 Pad Zeros To Length 20 Pad Zeros To Length 21 Pad Zeros To Length 22...
  • Page 277 Advanced Data Formatting 11 - 45 Pad Data with Zeros (continued) Pad Zeros To Length 25 Pad Zeros To Length 26 Pad Zeros To Length 27 Pad Zeros To Length 28 Pad Zeros To Length 29 Pad Zeros To Length 30 Stop Pad Zeros...
  • Page 278: Beeps

    11 - 46 Symbol DS6707 Digital Imager Scanner Product Reference Guide Beeps Select a beep sequence for each ADF rule. Beep Once Beep Twice Beep Three Times Send Keystroke (Control Characters and Keyboard Characters) Control Characters Scan a Send bar code for the keystroke to send.
  • Page 279 Advanced Data Formatting 11 - 47 Control Characters (continued) Send Control C Send Control D Send Control E Send Control F Send Control G Send Control H Send Control I...
  • Page 280 11 - 48 Symbol DS6707 Digital Imager Scanner Product Reference Guide Control Characters (continued) Send Control J Send Control K Send Control L Send Control M Send Control N Send Control O Send Control P...
  • Page 281 Advanced Data Formatting 11 - 49 Control Characters (continued) Send Control Q Send Control R Send Control S Send Control T Send Control U Send Control V Send Control W...
  • Page 282 11 - 50 Symbol DS6707 Digital Imager Scanner Product Reference Guide Control Characters (continued) Send Control X Send Control Y Send Control Z Send Control [ Send Control \ Send Control ]...
  • Page 283: Keyboard Characters

    Advanced Data Formatting 11 - 51 Control Characters (continued) Send Control 6 Send Control - Keyboard Characters Scan a Send bar code for the keyboard characters to send. Send Space Send ! Send “ Send #...
  • Page 284 11 - 52 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters (continued) Send $ Send % Send & Send ‘ Send ( Send ) Send *...
  • Page 285 Advanced Data Formatting 11 - 53 Keyboard Characters (continued) Send + Send , Send - Send . Send / Send 0 Send 1...
  • Page 286 11 - 54 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters (continued) Send 2 Send 3 Send 4 Send 5 Send 6 Send 7 Send 8...
  • Page 287 Advanced Data Formatting 11 - 55 Keyboard Characters (continued) Send 9 Send : Send ; Send < Send = Send > Send ?
  • Page 288 11 - 56 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters (continued) Send @ Send A Send B Send C Send D Send E Send F...
  • Page 289 Advanced Data Formatting 11 - 57 Keyboard Characters (continued) Send G Send H Send I Send J Send K Send L Send M...
  • Page 290 11 - 58 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters (continued) Send N Send O Send P Send Q Send R Send S Send T...
  • Page 291 Advanced Data Formatting 11 - 59 Keyboard Characters (continued) Send U Send V Send W Send X Send Y Send Z Send [...
  • Page 292 11 - 60 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters (continued) Send \ Send ] Send ^ Send _ Send ` Send a Send b...
  • Page 293 Advanced Data Formatting 11 - 61 Keyboard Characters (continued) Send c Send d Send e Send f Send g Send h Send i...
  • Page 294 11 - 62 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters (continued) Send j Send k Send l Send m Send n Send o Send p...
  • Page 295 Advanced Data Formatting 11 - 63 Keyboard Characters (continued) Send q Send r Send s Send t Send u Send v Send w...
  • Page 296 11 - 64 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters (continued) Send x Send y Send z Send { Send | Send } Send ~...
  • Page 297 Advanced Data Formatting 11 - 65 Send ALT Characters Send Alt 2 Send Alt A Send Alt B Send Alt C Send Alt D Send Alt E Send Alt F...
  • Page 298 11 - 66 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send ALT Characters (continued) Send Alt G Send Alt H Send Alt I Send Alt J Send Alt K Send Alt L Send Alt M...
  • Page 299 Advanced Data Formatting 11 - 67 Send ALT Characters (continued) Send Alt N Send Alt O Send Alt P Send Alt Q Send Alt R Send Alt S Send Alt T...
  • Page 300 11 - 68 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send ALT Characters (continued) Send Alt U Send Alt V Send Alt W Send Alt X Send Alt Y Send Alt Z Send Alt [...
  • Page 301 Advanced Data Formatting 11 - 69 Send ALT Characters (continued) Send Alt \ Send Alt ]...
  • Page 302 11 - 70 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Keypad Characters Send Keypad * Send Keypad + Send Keypad - Send Keypad . Send Keypad / Send Keypad 0 Send Keypad 1...
  • Page 303 Advanced Data Formatting 11 - 71 Send Keypad Characters (continued) Send Keypad 2 Send Keypad 3 Send Keypad 4 Send Keypad 5 Send Keypad 6 Send Keypad 7 Send Keypad 8...
  • Page 304 11 - 72 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Keypad Characters (continued) Send Keypad 9 Send Keypad Enter Send Keypad Numlock Send Break Key Send Delete Key Send Page Up Key Send End Key...
  • Page 305 Advanced Data Formatting 11 - 73 Send Keypad Characters (continued) Send Page Down Key Send Pause Key Send Scroll Lock Key Send Backspace Key Send Tab Key Send Print Screen Key Send Insert Key...
  • Page 306 11 - 74 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Keypad Characters (continued) Send Home Key Send Enter Key Send Escape Key Send Up Arrow Key Send Down Arrow Key Send Left Arrow Key Send Right Arrow Key...
  • Page 307 Advanced Data Formatting 11 - 75 Send Function Key Send F1 Key Send F2 Key Send F3 Key Send F4 Key Send F5 Key Send F6 Key Send F7 Key...
  • Page 308 11 - 76 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Function Key (continued) Send F8 Key Send F9 Key Send F10 Key Send F11 Key Send F12 Key Send F13 Key Send F14 Key...
  • Page 309 Advanced Data Formatting 11 - 77 Send Function Key (continued) Send F15 Key Send F16 Key Send F17 Key Send F18 Key Send F19 Key Send F20 Key Send F21 Key...
  • Page 310 11 - 78 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Function Key (continued) Send F22 Key Send F23 Key Send F24 Key Send PF1 Key Send PF2 Key Send PF3 Key Send PF4 Key...
  • Page 311 Advanced Data Formatting 11 - 79 Send Function Key (continued) Send PF5 Key Send PF6 Key Send PF7 Key Send PF8 Key Send PF9 Key Send PF10 Key Send PF11 Key...
  • Page 312 11 - 80 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Function Key (continued) Send PF12 Key Send PF13 Key Send PF14 Key Send PF15 Key Send PF16 Key Send PF17 Key Send PF18 Key...
  • Page 313 Advanced Data Formatting 11 - 81 Send Function Key (continued) Send PF19 Key Send PF20 Key Send PF21 Key Send PF22 Key Send PF23 Key Send PF24 Key Send PF25 Key...
  • Page 314: Send Right Control Key

    11 - 82 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Function Key (continued) Send PF26 Key Send PF27 Key Send PF28 Key Send PF29 Key Send PF30 Key Send Right Control Key The “Send Right Control Key” action will send a tap (press and release) of the Right Control Key.
  • Page 315: Send Graphic User Interface (Gui) Characters

    Advanced Data Formatting 11 - 83 Send Graphic User Interface (GUI) Characters The Send Graphic User Interface Character actions tap the specified key while holding the System Dependent Graphic User Interface (GUI) key. The definition of the Graphic User Interface key depends on the attached system.
  • Page 316 11 - 84 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Graphic User Interface (GUI) Characters (continued) Send GUI 6 Send GUI 7 Send GUI 8 Send GUI 9 Send GUI A Send GUI B Send GUI C...
  • Page 317 Advanced Data Formatting 11 - 85 Send Graphic User Interface (GUI) Characters (continued) Send GUI D Send GUI E Send GUI F Send GUI G Send GUI H Send GUI I Send GUI J...
  • Page 318 11 - 86 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Graphic User Interface (GUI) Characters (continued) Send GUI K Send GUI L Send GUI M Send GUI N Send GUI O Send GUI P Send GUI Q...
  • Page 319 Advanced Data Formatting 11 - 87 Send Graphic User Interface (GUI) Characters (continued) Send GUI R Send GUI S Send GUI T Send GUI U Send GUI V Send GUI W Send GUI X...
  • Page 320: Turn On/Off Rule Sets

    11 - 88 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Graphic User Interface (GUI) Characters (continued) Send GUI Y Send GUI Z Turn On/Off Rule Sets Use these bar codes to turn rule sets on and off. Turn On Rule Set 1...
  • Page 321 Advanced Data Formatting 11 - 89 Turn On/Off Rule Sets (continued) Use these bar codes to turn rule sets on and off. Turn Off Rule Set 1 Turn Off Rule Set 2 Turn Off Rule Set 3 Turn Off Rule Set 4...
  • Page 322: Alphanumeric Keyboard

    11 - 90 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard Space (Dash)
  • Page 323 Advanced Data Formatting 11 - 91 Alphanumeric Keyboard (continued) “ & ‘...
  • Page 324 11 - 92 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard (continued) < >...
  • Page 325 Advanced Data Formatting 11 - 93 Alphanumeric Keyboard (continued) (Underscore)
  • Page 326 11 - 94 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard (continued) NOTE Do not confuse the numeric bar codes below with those on the numeric keypad.
  • Page 327 Advanced Data Formatting 11 - 95 Alphanumeric Keyboard (continued)
  • Page 328 11 - 96 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard (continued)
  • Page 329 Advanced Data Formatting 11 - 97 Alphanumeric Keyboard (continued)
  • Page 330 11 - 98 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard (continued)
  • Page 331 Advanced Data Formatting 11 - 99 Alphanumeric Keyboard (continued) Cancel End of Message...
  • Page 332 11 - 100 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard (continued)
  • Page 333 Advanced Data Formatting 11 - 101 Alphanumeric Keyboard (continued)
  • Page 334 11 - 102 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard (continued)
  • Page 335 Advanced Data Formatting 11 - 103 Alphanumeric Keyboard (continued)
  • Page 336 11 - 104 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 337: Appendix A Standard Default Parameters

    Appendix A Standard Default Parameters Standard Default Parameters Table Table A-1 Parameter Page Parameter Default Number Number User Preferences Set Default Parameter Set All Defaults Parameter Scanning Enable Beeper Tone Medium Beeper Volume High Power Mode Continuous On Time Delay to Low Power Mode 1 Minute Trigger Mode Auto Aim...
  • Page 338 A - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Standard Default Parameters Table (Continued) Table A-1 Parameter Page Parameter Default Number Number Miscellaneous Scanner Options Transmit Code ID Character None 4-15 Prefix Value 63h, 69h 7013 <CR><LF> 4-16...
  • Page 339 Standard Default Parameters A - 3 Standard Default Parameters Table (Continued) Table A-1 Parameter Page Parameter Default Number Number JPEG Quality and Size Value F0h 31h 5-15 Image Enhancement F1h 34h Off (0) 5-16 Image File Format Selection F0h 30h JPEG 5-17 Bits per Pixel (BPP)
  • Page 340 A - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide Standard Default Parameters Table (Continued) Table A-1 Parameter Page Parameter Default Number Number Parameter Event F0h 03h Disable 6-15 USB Host Parameters USB Device Type HID Keyboard Emulation Symbol Native API (SNAPI) Status...
  • Page 341: Upc/Ean

    Standard Default Parameters A - 5 Standard Default Parameters Table (Continued) Table A-1 Parameter Page Parameter Default Number Number Nixdorf Beep/LED Options Normal Operation 8-18 Ignore Unknown Characters Send Bar Code 8-18 123Scan Configuration Tool 123Scan Configuration None UPC/EAN UPC-A Enable 10-7 UPC-E...
  • Page 342: Code 128

    A - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide Standard Default Parameters Table (Continued) Table A-1 Parameter Page Parameter Default Number Number Code 128 Code 128 Enable 10-23 Set Length(s) for Code 128 D1h D2h Any Length 10-23...
  • Page 343 Standard Default Parameters A - 7 Standard Default Parameters Table (Continued) Table A-1 Parameter Page Parameter Default Number Number Convert I 2 of 5 to EAN 13 Disable 10-43 Discrete 2 of 5 (DTF) Discrete 2 of 5 Disable 10-44 Set Length(s) for D 2 of 5 14h 15h 10-44...
  • Page 344: Gs1 Databar-14

    A - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide Standard Default Parameters Table (Continued) Table A-1 Parameter Page Parameter Default Number Number GS1 DataBar GS1 DataBar-14 F0h 52h Enable 10-58 GS1 DataBar Limited F0h 53h Enable 10-58 GS1 DataBar Expanded...
  • Page 345 Standard Default Parameters A - 9 Standard Default Parameters Table (Continued) Table A-1 Parameter Page Parameter Default Number Number Symbology-Specific Security Levels Redundancy Level 10-73 Security Level 10-75 Intercharacter Gap Size F0h 7Dh Normal 10-76 Report Version 10-76 Macro PDF Flush Macro PDF Buffer 10-77 Abort Macro PDF Entry...
  • Page 346 A - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 347 Appendix B Programming Reference Symbol Code Identifiers Symbol Code Characters Table B-1 Code Character Code Type UPC-A, UPC-E, UPC-E1, EAN-8, EAN-13 Code 39, Code 32 Codabar Code 128 Code 93 Interleaved 2 of 5 Discrete 2 of 5, or Discrete 2 of 5 IATA Code 11 GS1-128 Bookland EAN...
  • Page 348 B - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Symbol Code Characters (Continued) Table B-1 Code Character Code Type Data Matrix QR Code, MicroQR Maxicode US Postnet US Planet Japan Postal UK Postal Dutch Postal Australian Postal 4State Postal...
  • Page 349 Programming Reference B - 3 AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: = Flag Character (ASCII 93) c = Code Character (see Table B-2) m = Modifier Character (see Table B-3) Aim Code Characters Table B-2 Code Character Code Type...
  • Page 350 B - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide The modifier character is the sum of the applicable option values based on Table B-3. Modifier Characters Table B-3 Code Type Option Value Option Code 39 No check character or Full ASCII processing.
  • Page 351 Programming Reference B - 5 Modifier Characters (Continued) Table B-3 Code Type Option Value Option D 2 of 5 No options specified at this time. Always transmit 0. Example: A D 2 of 5 bar code 4123, is transmitted as ]S04123 UPC/EAN Standard packet in full EAN country code format, which is 13 digits for UPC-A, UPC-E, and EAN-13 (not including supplemental data).
  • Page 352 B - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide Modifier Characters (Continued) Table B-3 Code Type Option Value Option PDF417, Reader set to conform to protocol defined in 1994 PDF417 symbology Micro PDF417 specifications. Note: When this option is transmitted, the receiver cannot reliably determine whether ECIs have been invoked or whether data byte has been doubled in transmission.
  • Page 353 Programming Reference B - 7 Modifier Characters (Continued) Table B-3 Code Type Option Value Option QR Code Model 1 symbol. Model 2 / MicroQR symbol, ECI protocol not implemented. Model 2 symbol, ECI protocol implemented. Model 2 symbol, ECI protocol not implemented, FNC1 implied in first position.
  • Page 354 B - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 355: Appendix C: Sample Bar Codes Code 39

    Appendix C Sample Bar Codes Code 39 123ABC UPC/EAN UPC-A, 100% 12345 67890...
  • Page 356 C - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide EAN-13, 100% 3 456789 012340 Code 128 12345678901234567890123456789012345678901234 Interleaved 2 of 5 12345678901231...
  • Page 357: Data Matrix

    Sample Bar Codes C - 3 GS1 DataBar-14 NOTE GS1 DataBar-14 must be enabled to read the bar code below (see GS1 DataBar-14 on page 10-58). 7612341562341 PDF417 Data Matrix...
  • Page 358: Maxicode

    C - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide Maxicode QR Code US Postnet...
  • Page 359: Uk Postal

    Sample Bar Codes C - 5 UK Postal...
  • Page 360 C - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide...
  • Page 361: Appendix D: Numeric Bar Codes

    Appendix D Numeric Bar Codes Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).
  • Page 362: Cancel

    D - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Numeric Bar Codes (continued) Cancel To correct an error or change a selection, scan the bar code below. Cancel...
  • Page 363: Appendix E Ascii Character Sets

    Appendix E ASCII Character Sets ASCII Value Table Table E-1 Full ASCII Code 39 ASCII Value Keystroke Encode Char 1000 CTRL 2 1001 CTRL A 1002 CTRL B 1003 CTRL C 1004 CTRL D 1005 CTRL E 1006 CTRL F 1007 CTRL G 1008...
  • Page 364 E - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide ASCII Value Table (Continued) Table E-1 Full ASCII Code 39 ASCII Value Keystroke Encode Char 1016 CTRL P 1017 CTRL Q 1018 CTRL R 1019 CTRL S 1020 CTRL T...
  • Page 365 ASCII Character Sets E - 3 ASCII Value Table (Continued) Table E-1 Full ASCII Code 39 ASCII Value Keystroke Encode Char 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 < 1061 1062 >...
  • Page 366 E - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide ASCII Value Table (Continued) Table E-1 Full ASCII Code 39 ASCII Value Keystroke Encode Char 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085...
  • Page 367 ASCII Character Sets E - 5 ASCII Value Table (Continued) Table E-1 Full ASCII Code 39 ASCII Value Keystroke Encode Char 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121...
  • Page 368 E - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide ALT Key Standard Default Tables Table E-2 ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070...
  • Page 369 ASCII Character Sets E - 7 USB GUI Key Character Set Table E-3 GUI Key Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056...
  • Page 370 E - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide USB GUI Key Character Set (Continued) Table E-3 GUI Key Keystroke 3080 GUI P 3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U...
  • Page 371 ASCII Character Sets E - 9 PF Key Standard Default Table Table E-4 PF Keys Keystroke 4001 PF 1 4002 PF 2 4003 PF 3 4004 PF 4 4005 PF 5 4006 PF 6 4007 PF 7 4008 PF 8 4009 PF 9 4010...
  • Page 372 E - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide F key Standard Default Table Table E-5 F Keys Keystroke 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 F 10 5011 F 11 5012 F 12 5013...
  • Page 373 ASCII Character Sets E - 11 Numeric Key Standard Default Table Table E-6 Numeric Keypad Keystroke 6042 6043 6044 Undefined 6045 6046 6047 6048 6049 6050 6051 6052 6053 6054 6055 6056 6057 6058 Enter 6059 Num Lock...
  • Page 374 E - 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide Extended Keypad Standard Default Table Table E-7 Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009...
  • Page 375 Glossary Aperture. The opening in an optical system defined by a lens or baffle that establishes the field of view. API. An interface by means of which one software component communicates with or controls another. Usually used to refer to services provided by one software component to another, usually via software interrupts or function calls Application Programming Interface.
  • Page 376 Glossary - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Bit. Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning.
  • Page 377 Glossary - 3 Code Length. Number of data characters in a bar code between the start and stop characters, not including those characters. Cold Boot. A cold boot restarts the mobile computer and erases all user stored records and entries. COM Port.
  • Page 378 Glossary - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide Flash Disk. An additional megabyte of non-volatile memory for storing application and configuration files. Flash Memory. Flash memory is responsible for storing the system firmware and is non-volatile. If the system power is interrupted the data is not be lost.
  • Page 379 Glossary - 5 IP. Internet Protocol. The IP part of the TCP/IP communications protocol. IP implements the network layer (layer 3) of the protocol, which contains a network address and is used to route a message to a different network or subnetwork. IP accepts “packets”...
  • Page 380 Glossary - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide MIN are the same value for voice cellular users. International roaming considerations often result in the MDN being different from the MIN. MIL. 1 mil = 1 thousandth of an inch.
  • Page 381 Glossary - 7 PCMCIA. Personal Computer Memory Card Interface Association. See PC Card. Percent Decode. The average probability that a single scan of a bar code would result in a successful decode. In a well-designed bar code scanning system, that probability should approach near 100%. PING.
  • Page 382 Glossary - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide Scanner. An electronic device used to scan bar code symbols and produce a digitized pattern that corresponds to the bars and spaces of the symbol. Its three main components are: 1) Light source (laser or photoelectric cell) - illuminates a bar code,;...
  • Page 383 Glossary - 9 Symbology. The structural rules and conventions for representing data within a particular bar code type (e.g. UPC/EAN, Code 39, PDF417, etc.). TCP/IP. (Transmission Control Protocol/Internet Protocol) A communications protocol used to internetwork dissimilar systems. This standard is the protocol of the Internet and has become the global standard for communications. TCP provides transport functions, which ensures that the total amount of bytes sent is received correctly at the other end.
  • Page 384 Glossary - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide Visible Laser Diode (VLD). A solid state device which produces visible laser light. Warm Boot. A warm boot restarts the mobile computer by closing all running programs. All data that is not saved to flash...
  • Page 385 Index Numerics pad spaces ......11-37 pad zeros ......11-41 123Scan parameters .
  • Page 386 Index - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide pad zeros ......11-41 code 11 .
  • Page 387 Index - 3 image cropping ......5-11 security level ......10-75 image enhancement .
  • Page 388 Index - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide beeper definitions ......2-2 notational .
  • Page 389 ......2-7 Motorola enterprise mobility support ....xv sequence example .
  • Page 390 Index - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide unpacking ......1-2 signal descriptions .
  • Page 391: Tell Us What You Think

    We’d like to know what you think about this Manual. Please take a moment to fill out this questionnaire and fax this form to: (631) 738-4618, or mail to: Motorola, Inc. One Motorola Plaza M/S B-10 Holtsville, NY 11742-1300 Attention:...
  • Page 394 1-800-927-9626 http://www.motorola.com/enterprisemobility MOTOROLA and the Stylized M Logo and Symbol and the Symbol logo are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their respective owners. © Motorola, Inc. 2008...

Table of Contents