Sony HVR-A1J Service Manual page 198

Digital hd video camera recorder
Table of Contents

Advertisement

13. LV Standard Data Input
Adjust the normal coefficient of the light value at 3200K.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Perform "F No. & ND Light Quality Standard Data In-
put" and "Auto White Balance Standard Data Input" be-
fore this adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 3: Check that the data of page: 6, address: 02 is "00". If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
HVR-A1J/A1U/A1N/A1E/A1P/A1C
RadarW
RadarW
RadarW
RadarW
RadarW
Clear chart (All white frame)
Displayed data of page: 1 (Note 4)
Adjusting remote commander
6F
2A, 2B
0FE0 to 1020
Displayed data
Adjusting method:
Order Page Address Data
1
2
0
01
3
6
4D
4
6
C9
5
6
6
01
7
6
02
8
0
03
9
1
Note 5: The adjustment data will be automatically input to page:
6F, address: 2A, 2B.
Processing after Completing Adjustment:
Order Page Address Data
1
6
4D
2
6
C9
3
6
01
4
0
03
5
0
01
6-39
Procedure
Check that the picture frame
is "All White Frame". If not,
perform "11. Picture Frame
Setting (All White Frame)"
01
40
10
Wait for 6 seconds.
Press PAUSE (Write) button.
0D
(Note 5)
Check the data changes to
"01".
1E
Check that the displayed data
(Note 4) satisfied the
specified value.
Procedure
00
00
00
Press PAUSE (Write) button.
00
00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvr-a1pHvr-a1cRmt-831Hvr-a1eHvr-a1uHvr-a1n