Convenience Operation; Care And Maintenance - Panasonic CS-V12CTP Service Manual

Room air conditioner
Hide thumbs Also See for CS-V12CTP:
Table of Contents

Advertisement

CS-V12CTP CU-V12CTP5 / CS-V18CTP CU-V18CTP5 / CS-V24CTP CU-V24CTP5
I Setting the Fan Speed
• Press 4 to select:-
FAN
– Low Fan Speed
FAN
– Medium Fan Speed
FAN
– High Fan Speed
AUTO
FAN
– Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Vertical Airflow Direction
G Manual Operation
• Press and hold the Manual Airflow Direction
Selection Button 5 , then release the button at
the desired airflow direction.
• Cooling / Soft Dry/
Heating (for Heat-Pump Model only)
The airflow direction can be adjusted as desired
by using the remote control. This is effective
when you want to cool yourself directly, such as
when coming out of the bath. The louver can be
adjusted within a range between the horizontal
and 25 degrees downward at Cooling and Soft
Dry Operation, and between the horizontal and
45 degrees downward at Heating Operation.
(for Heat-Pump Model only)
Horizontal
5
3
2
1
4
SETTING THE TIMER
• Press the Timer Selection Button 1.
• Timer indicator on the indoor unit will light up.
• Select one of the following five types of operation.
Each time the button is pressed, the operation mode
is shifted in the arrow direction.
Delay OFF Timer
OFF
Delay ON Timer
Delay OFF and
ON Timer
OFF
Delay ON and
OFF Timer
• Then press the Timer Setting Button 2 or 3 to the
desired number of hours.
(Number of hours which can be set : 1 ~ 12)
• Press the Timer Set/Cancel Button 4.
G Automatic Operation
Downward

CONVENIENCE OPERATION

I Sleep Mode Operation
To obtain a comfortable room temperature while sleeping:-
• Press 5.
• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
G Sleep Mode Operation Details
• When the room temperature reaches the set temperature,
the airflow volume will change to low automatically.
• Sleep Mode Operation time is 8 hours.
• When used together with the timer, the timer has a priority.
Temperature
S
T
e
e
m
Example :
t
p
t
Operation Stops
e
i
r
after 1 hour
n
a
H
ON Timer.
g
t
u
r
e
Example :
Operation starts after
6 hours.
H
ON
Temperature
Example :
S
T
Operation stops after
e
e
1 hour and re-starts
m
t
H
H
p
after another 5 hours.
t
ON
e
i
r
n
a
g
t
u
Example :
r
e
Operation starts after
10 hours, and then
H
H
stops after another 8
ON
OFF
hours.
• Press the Auto Airflow Direction Button 6.
• Cooling / Soft Dry
The louver will automatically swing up and down
to create the feeling of a refreshing breeze.
• Heating (for Heat-Pump Model only)
When the discharge air temperature is low such
as at starts of heating operation, the air blows at
horizontal level.
As the temperature rises, the hot air blows in a
downwards direction.
Cooling Model
Approx. 0.5°C
increase.
Approx.
0.5°C
increase.
• Cooling or Soft Dry
Sleep
Operation for sleep shift
Operation
operation will start to
Sleep shift
button is
avoid overcooling.
operation
pressed.
starts.
← 1 hour →
0~1 hour
Time
after approx. 8 hours of sleep shift
operation, it will stop automatically.
Heat Pump Model
Approx. 0.5°C
increase.
Approx.
0.5°C
increase.
• Cooling or Soft Dry
Operation for sleep shift
operation will start to
avoid overcooling.
Sleep shift
operation starts.
• Heating operation for
sleep shift operation will
Sleep
start to avoid overheating.
Operation
Approx. 2°C
button is
← 1 hour →
decrease.
pressed.
Approx. 3°C
← 1 hour →
decrease.
0~1 hour
Time
after approx. 8 hours of sleep shift
operation, it will stop automatically.
26
I Setting the Horizontal Airflow Direction
• Adjust it manually
G Use this air conditioner under the following
conditions:
Cooling Model
(Unit in °C)
Indoor
Outdoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
DBT
WBT
Maximum Temperature
32
23
43
16
11
16
Minimum Temperature
Heat Pump Model
(Unit in °C)
Outdoor
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
DBT
WBT
Maximum Temperature-Cooling
32
23
43
(Maximum Temperature-Heating)
(30)
(-)
(24)
(18)
Minimum Temperature-Cooling
16
11
16
(Minimum Temperature-Heating)
(16)
(-)
(-5)
(-6)
G Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.0 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.

CARE AND MAINTENANCE

I Cleaning the Indoor Unit and Remote
Control
• Wipe gently with a soft, dry cloth.
• Do not use water hotter than 40˚C or polishing fluid
to clean the unit.
I Cleaning the Air Filter
(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency)
1
Remove dirt using a vacuum cleaner.
2
Wash back of the air filter with water.
3
If badly soiled, wash it with soap or a mild household
detergent.
4
Let it dry and reinstall it.
Be sure the "FRONT" mark is facing you.
* Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD001088.
• Do not use benzene, thinner, scouring powder or
clothes soaked in caustic chemical to clean the
unit.
26
11
26
11