Operating Instructions - Panasonic CS-V12CTP Service Manual

Room air conditioner
Hide thumbs Also See for CS-V12CTP:
Table of Contents

Advertisement

CS-V12CTP CU-V12CTP5 / CS-V18CTP CU-V18CTP5 / CS-V24CTP CU-V24CTP5

8 Operating Instructions

SAFETY PRECAUTIONS
Before operating, please read the following
"Safety Precautions" carefully.
G To prevent personal injury, injury to others and
property damage, the following instructions must be
followed.
G Incorrect operation due to failure to follow instructions
will cause harm or damage, the seriousness of which
is classified as follow:
!
This sign warns of death or serious injury.
!
This sign warns of damage to property.
G The instructions to be followed are classified by the
following symbols:
This symbol (with a white background) denotes an
action that is PROHIBITED.
These symbols (with a black background) denote
actions that are COMPULSORY.
NAME OF EACH PART
I Indoor Unit
6
1
5
1 Air Outlet Vent
2 Power Supply Cord
3 Air Intake Vent
4 Air Filters (behind the panel)
5 Horizontal Airflow Direction Louver
(manually adjusted)
6 Vertical Airflow Direction Louver
G Indoor Unit Controls
1
2
1 Operation Indication Lamps
2 Signal Receptor
I Installation Precautions
G Do not install, remove and reinstall the unit by
yourself.
Improper installation will cause leakage, electric
shock or fire. Please engage an authorized dealer
or specialist for the installation work.
Warning
Caution
2
1 Auto Operation Button
2 Power Mode Indicator
3
3 Timer Mode Indicator
4
4 Sleep Mode Indicator
5 Air Swing Mode Indicator
I Outdoor Unit
1 Air Intake Vents
2 Piping
3 Connecting Cable
!
Warning
!
Caution
G This room air conditioner must be
earthed.
Improper grounding could cause
electric shock.
G Ensure that the drainage piping is
connected properly.
Otherwise, water will leak out.
G Do not install the unit in a
potentially explosive atmosphere.
Gas leak near the unit could cause
fire.
AUTO OFF/ON
POWER
TIMER
SLEEP
AIR SWING
1
2
3 4 5
– GREEN
– ORANGE
– ORANGE
– ORANGE
1
2
3
5
4
CU-V18CTP5, CU-V24CTP5
CU-A18CTP5, CU-A24CTP5
4 Air Outlet Vents
5 Drain Hose
CU-V12CTP5
CU-A12CTP5
24
I Operation Precautions
!
Warning
This sign warns of death or serious injury.
G Do not share outlet.
G Do not insert plug to operate the unit. Do not
pull out plug to stop the unit.
G Do not operate with wet hands.
G Do not damage or modify the power cord.
G Do not insert finger or other objects into the
indoor or outdoor units.
G Do not expose directly to cold air for a long period.
G Plug in properly.
G Use specified power cord.
G If abnormal condition (burnt smell, etc.)
occurs, switch off and unplug the power
supply.
!
Caution
This sign warns of injury.
G Do not pull the cord to disconnect the plug.
G Do not wash the unit with water.
G Do not use for other purposes such as
preservation.
G Do not use any combustible equipment at
airflow direction.
G Do not sit or place anything on the indoor or
outdoor unit.
G Switch off the power supply before cleaning.
G Ventilate the room regularly.
G Pay attention as to whether the installation
rack is damaged after long period of usage.
G Switch off the power supply if the unit is not
used for a long period.
I Accessories
G Remote Control
G Remote Control Indication Sticker
G Remote Control Holder
G Two RO3 (AAA) dry-cell batteries or equivalent