To clean the drain pump:

1
2
1.
Open the drain pump door.
2.
Pull the flap out to remove it.
3.
Put a container below the recess of
the drain pump to collect the water
that flows out.
4.
Press the two levers and pull for-
ward the drainage duct to let the
water flow out.
5.
When the container is full of water,
put the drainage duct back again
and empty the container. Do steps 4
and 5 again and again until no more
water flows out from the drain
pump.
6.
Pull back the drainage duct and turn
the filter to remove it.
7.
Remove fluff and objects from the
pump.
8.
Make sure that the impeller of the
pump can turn. If this does not oc-
cur, contact the service centre.