Charge Mode - La Crosse Technology BC-9009U Instruction Manual

La crosse technology battery charger instruction manual
Table of Contents

Advertisement

CHARGE MODE

Charging at 200 mA is the default-operating mode of the charging unit.
When only one or two rechargeable batteries are charged, provided that only compartment 1
and compartment 4 are used, a charging current up to 1500 or 1800 mA may be set by the
pressing the CURRENT key.
On the other hand, when charging three or four rechargeable batteries at the same time, user
may select a charging current of 200, 500, 700 or 1000 mA.
When charging two batteries at
compartment 1 & 4 – max.
charging current: 1800 mA
Table 1. Charging Time with various charging current
Size of battery
Battery Capacity
Charging current selected
AA
2600 mAh
AA
2000 mAh
AAA
1000 mAh
When charging two batteries at
compartment 1 & 2 – max.
charging current: 1000 mA
8
Estimated charging time
(mA)
1800
~80 min
1500
~100 min
1000
~2 hr 30 min
700
~3 hr 30 min
500
~5 hr
200
~12 hr
1800
~70 min
1500
~80 min
1000
~2 hr
700
~3 hr
500
~4 hr
200
~10 hr
700
~70 min
500
~1 hr 40 min
10
When charging two batteries at
compartment 2 & 3 – max.
charging current: 1000 mA
The estimated time of charging by various charging current is tabulated in Table 1.
Note:
User shall always observe the recommended maximum charging current of the
rechargeable batteries. In general, 200 mA is a recommended charging current if rapid
charging is not necessary. It is definitely safe and optimum to the rechargeable
batteries.
It may be necessary to charge and discharge the new rechargeable batteries several
times in the beginning before the optimum capacity of the rechargeable batteries can
be obtained. It is recommended to use the "Refresh" mode for new rechargeable
batteries in order to achieve the optimum battery capacity.
When the transformer has been plugged into the power source, the version number of
the charger (for example "33" ) will be displayed first. Then all the segments will light up
momentarily and the "null" sign will be shown before batteries are placed. If damaged
batteries are placed into the charging unit, the charger will also show "null" on LCD.
"null" displayed - No battery or damaged battery is
placed to the charging unit
When charging four batteries –
max. charging current: 1000 mA
9
200
~4 hr
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents