Disassembly Instructions; Terminal With Locking Mechanism; Removing Cabinet And Panels - Mitsubishi Electric Mr.Slim MUZ-GC25NA - C1 Service Manual

Outdoor unit split-type air conditioners
Table of Contents

Advertisement

10

DISASSEMBLY INSTRUCTIONS

<"Terminal with locking mechanism" Detaching points>
The terminal which has the locking mechanism can be detached as shown below.
There are two types ( Refer to (1) and (2)) of the terminal with locking mechanism.
The terminal without locking mechanism can be detached by pulling it out.
Check the shape of the terminal before detaching.
(1) Slide the sleeve and check if there is a locking lever or not.
Sleeve
Locking lever
10-1. MUZ-GC25NA MUZ-GC35NA
OPERATING PROCEDURE

1. Removing cabinet and panels

(1) Remove the screw fixing the service panel. (Photo 2.)
(2) Pull down the service panel and remove it. (Photo 2.)
(3) Disconnect the power supply and indoor/outdoor connect-
ing wire.
(4) Remove the screws fixing the top panel. (Photo 1.)
(5) Remove the top panel. (Photo 1.)
(6) Remove the screws fixing the cabinet. (Photo 1.)
(7) Remove the cabinet.
(8) Remove the screws fixing the back panel.
(9) Remove the back panel.
Photo 2
Slide the sleeve.
Pull the terminal while
pushing the locking
lever.
Photo 1
Screw of the
service panel
Direction to
remove
Hooks
Hooks
54
(2) The terminal with this connector has the
locking mechanism.
Hold the sleeve, and
pull out the terminal
slowly.
Connector
NOTE : Turn OFF power supply before disassembling.
PHOTOS
Screws
of the
top panel
Screws of
the cabinet
Screws of
the top panel
Service
panel

Hide quick links:

Advertisement

Table of Contents
loading