MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
Model
MUZ-GC25NA
MUZ-GC35NA
MUZ-GC50NA
MUZ-GC60NA
MUZ-GC71NA
ADDITIONAL REFRIGERANT CHARGE (R410A : g)
Outdoor unit
Model
precharged
MUZ-GC25NA
750
MUZ-GC35NA
Outdoor unit
Model
precharged
MUZ-GC50NA
1,500
MUZ-GC60NA
1,800
Outdoor unit
Model
precharged
MUZ-GC71NA
2,000
NOTE : Refrigerant piping exceeding 7 m requires additional refrigerant charge according to the calculation.
Refrigerant piping : m
Max. Length
A
20
30
Indoor
unit
Max. Height
difference
B
Max. Length
5 m
6 m
7 m
0
0
0
7 m
0
7 m
0
Max. Height difference
B
12
15
A
Outdoor unit
Refrigerant piping length (one way)
8 m
9 m
10 m
90
120
150
Calculation : X g = 30 g/m × (Refrigerant piping length (m) – 5)
Refrigerant piping length (one way)
10 m
15 m
60
160
Calculation : X g = 20 g/m × (Refrigerant piping length (m) – 7)
Refrigerant piping length (one way)
10 m
15 m
165
440
Calculation : X g = 55 g/m × (Refrigerant piping length (m) – 7)
17
Piping size O.D : mm
Gas
9.52
12.7
15.88
11 m
12 m
13 m
14 m
180
210
240
270
20 m
25 m
260
360
20 m
25 m
715
990
Liquid
6.35
9.52
15 m
20 m
300
450
30 m
460
30 m
1,265