5-1-5 Removing the Power PCB
1. Complete all previous steps.
2. Disconnect CN603 on the Power PCB.
3. Remove the screw on the lower side of the
SMPS Bracket.
4. Lift off the Power PCB Assembly.
5. Remove the Shield Cover and disconnect
CN601 on the Power PCB.
Figure 5-9
6. Remove the 4 screws on the Power PCB.
7. Lift out the Power PCB and place it on a flat,
level surface that is protected from static
electricity.
Figure 5-10
SyncMaster 1000s (CGP1607L)
5-1-6 Removing the Main PCB
1. Complete all previous steps.
2. Remove the 7 screws on the Main PCB.
3. Carefully lift out the Main PCB and place it on
a flat, level surface that is protected from static
electricity.
Figure 5-11
5-1-7 Disassembling the CRT Assembly
1. Complete all previous steps.
Figure 5-12
2. Remove the 1 screw on the CRT frame.
3. Remove the 2 screws on the Bottom frame.
4. Remove the other 10 screws and lift off the
CRT frame.
5. Straighten the Degaussing Coil Assembly
coated metal ties and lift the Coil from the
CRT.
6. Lift the CRT up and away from the Front
Cover Assembly and place it on a padded
surface.
Do not lift the CRT by the neck.
!