Toner Cartridge Improper Cartridge Detection (Cyan); Toner Cartridge Improper Cartridge Detection (Magenta); Toner Cartridge Improper Cartridge Detection (Yellow); Toner Cartridge Crum Error (Black) - Sharp MX-2300 G Service Manual

Digital full color multifunctional system
Hide thumbs Also See for MX-2300 G:
Table of Contents

Advertisement

F2-71
Toner cartridge improper cartridge
detection (CYAN)
Trouble content
Improper data are detected in the CRUM contents
when the normal CRUM of the cartridge is detected.
Section
PCU
Case 1
Cause
An improper cartridge is inserted. Toner cartridge
trouble
Check
Replace the toner cartridge.
and
remedy
F2-72
Toner cartridge improper cartridge
detection (MAGENTA)
Trouble content
Improper data are detected in the CRUM contents
when the normal CRUM of the cartridge is detected.
Section
PCU
Case 1
Cause
An improper cartridge is inserted. Toner cartridge
trouble
Check
Replace the toner cartridge.
and
remedy
F2-73
Toner cartridge improper cartridge
detection (YELLOW)
Trouble content
Improper data are detected in the CRUM contents
when the normal CRUM of the cartridge is detected.
Section
PCU
Case 1
Cause
An improper cartridge is inserted. Toner cartridge
trouble
Check
Replace the toner cartridge.
and
remedy
F2-74

Toner cartridge CRUM error (BLACK)

Trouble content
CRUM cannot be read or written.
Section
PCU
Case 1
Cause
Connection trouble or disconnection of the connector
and the harness between the PCU and the toner
cartridge.
Check
Check the connector and the harness between the
and
PCU and the toner cartridge.
remedy
Case 2
Cause
CRUM trouble
Check
Replace the toner cartridge.
and
remedy
Case 3
Cause
Control PWB (PCU) trouble
Check
Replace the PCU PWB.
and
remedy
MX-2300/2700 N/G SELF DIAG AND TROUBLE CODE 8 – 18
F2-75
Toner cartridge CRUM error (CYAN)
Trouble content
CRUM cannot be read or written.
Section
PCU
Case 1
Cause
Connection trouble or disconnection of the connector
and the harness between the PCU and the toner
cartridge.
Check
Check the connector and the harness between the
and
PCU and the toner cartridge.
remedy
Case 2
Cause
CRUM trouble
Check
Replace the toner cartridge.
and
remedy
Case 3
Cause
Control PWB (PCU) trouble
Check
Replace the PCU PWB.
and
remedy
F2-76
Toner cartridge CRUM error
(MAGENTA)
Trouble content
CRUM cannot be read or written.
Section
PCU
Case 1
Cause
Connection trouble or disconnection of the connector
and the harness between the PCU and the toner
cartridge.
Check
Check the connector and the harness between the
and
PCU and the toner cartridge.
remedy
Case 2
Cause
CRUM trouble
Check
Replace the toner cartridge.
and
remedy
Case 3
Cause
Control PWB (PCU) trouble
Check
Replace the PCU PWB.
and
remedy
F2-77
Toner cartridge CRUM error
(YELLOW)
Trouble content
CRUM cannot be read or written.
Section
PCU
Case 1
Cause
Connection trouble or disconnection of the connector
and the harness between the PCU and the toner
cartridge.
Check
Check the connector and the harness between the
and
PCU and the toner cartridge.
remedy
Case 2
Cause
CRUM trouble
Check
Replace the toner cartridge.
and
remedy
Case 3
Cause
Control PWB (PCU) trouble
Check
Replace the PCU PWB.
and
remedy