Ceiling Concealed Duct Type
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Required Parts
• Connecting cable
• Pipes: Gas side
Liquid side
• Hanging Bolt
(W 3/8 or M10 length 650mm)
• Insulated drain hose
• Additional Drain hose
(Outer Dia ................................25.4mm)
1. Selection of the best location
Install the air conditioner in the location that satisfies the fol-
lowing conditions.
• The place shall easily bear a load exceeding four times the
indoor unit's weight.
• The place should have enough area for inspection as shown
in figure.
• The place where the unit shall be leveled.
• The place shall allow easy water drainage.(Suitable dimen-
sion "H" is necessary to get a slope to drain as figure.)
• The place shall easily connect with the outdoor unit.
• The place where the unit is not affected by an electrical
noise.
• The place where air circulation in the room will be good .
• There should not be any heat source or steam near the unit.
Air outlet vents
Air intake vents
Wired LCD Remote Control

Required Tools

• Level
• Screw driver
• Electric drill
• Hole core drill (ø70mm)
• Flaring Tools set
• Torque Wrenches
• Hexagonal Wrench (4mm, 5mm)
• Gas-leak detector
• Owner's Manual
• Thermometer
Air filters
Top view
Inspection hole
(unit: mm)
(600X600)
Control box
600
Front
Front view
Installation
600
H
Service Manual 37