Connect Power

12
Follow these steps to connect power. The
switchplate supplies power to both the antenna
and the MCP.
a. Before you begin, disconnect vessel power.
For your own safety, disconnect vessel power
and make sure the circuit is dead before you
connect any power wires.
b. Route a set of power wires from the
switchplate's power output terminals to the
MCP (for cable specifications, see Figure 2 on
page 3). Connect the wires to the plastic
power plug supplied in the kitpack (see
Figure 27).
NOTE: You should now have three wires
connected to each power output terminal on the
switchplate: one set of wires to power the antenna,
one set to power the MCP, and one set to power
the switchplate's indicator lamp (installed at the
factory).
c. Tighten the terminal screws on the
switchplate to secure all wires in place.
d. Plug the MCP power plug into the "Power
In" jack on the MCP (see Figure 28). Secure in
place with the retaining screws.
e. Connect a power cable to 12 VDC vessel
power (for cable specifications, see Figure 2
on page 2).
IMPORTANT!
Power supplied to the antenna must not fall
below 11 VDC or exceed 16 VDC.
f. Connect your vessel power wires to the
power (+) and ground (-) input terminals on
the switchplate (see Figure 29).
14
CAUTION
Figure 27: MCP Power Plug
Terminal Screw (x2)
Power
Ground
Figure 28: MCP Power Wiring
MCP
HDTV
ANTENNA UNIT
RF PORT
TONE
FUSE
CONTROL
DETECT
Figure 29: Switchplate Wiring - Vessel Power Cable
Vessel Power
Ground
11-16 VDC
Retaining Screw (x2)
+ –
Switchplate-to-MCP
Power Cable
+
POWER IN
+ / –
+