Compressor Replacement - Cornelius TS-009 Repair Manual

Home ice cream maker cornelius ts-009
Table of Contents

Advertisement

REFRIGERATION INSTALLATIONS LIMITED
Unit D9 Newton Business Park
Cartwright Street
Hyde
Cheshire SK14 4EH
Telephone: +44 (0)161 366 1110
Fax: +44 (0)161 366 1190

10.6 Compressor Replacement

10.6.1 When a compressor fault is suspected, as determined in
Section 8.6, and replacement of the compressor is required the
machine should be dismantled as described in Section 9.
10.6.2 Remove any cable ties that are holding wiring to any of the
compressor parts or pipes and disconnect the compressor wiring
from the connector block. Remove any insulation that could get
damaged in subsequent brazing operations.
10.6.3 Pierce the suction pipe as shown in the picture with a pair of
piercing pliers.
Suction pipe
10.6.4
Connect the pierced suction pipe to an appropriate gas
recovery system via a service hose and recover the refrigerant
gas.
D ocument Reference: WI 9
Page 21 of 21
Issue 02