10.4 PCB and Motor Connector Replacement (Continued)
10.4.2 Continued

10.5 Mains Lead Replacement

10.5.1 Remove the two Philips head screws that attach the cable
clamp and remove the clamp. Remove the glue from around the
cable entry grommet and slide the grommet out of its slot. Remove
any necessary cable ties to allow the connector block to be
removed from its seating and release the three mains lead
conductors from the block. Replacement is the reverse process.
Cable
clamp and
screws
D ocument Reference: WI 9
Issue 02
Unit D9 Newton Business Park
Cartwright Street
Hyde
Cheshire SK14 4EH
Fax: +44 (0)161 366 1190
Transformer
Buzzer
Connector
block
Cable entry
grommet