Replacing The Power Supply - Bosch DIP-7080-00N Installation Manual

Divar ip 7000 2u
Hide thumbs Also See for DIP-7080-00N:
Table of Contents

Advertisement

22
en | Chassis setup and maintenance
LED status:
Warning!
Redundant power supplies
!
This unit might have more than one power supply connection. To de-energize the unit, remove
all connections.
3.11.1

Replacing the power supply

The power supply can be replaced without turning off the system if a redundant power supply
is available. Replacement units can be ordered directly from Bosch RMA desk.
To replace the power supply:
1.
2.
3.
4.
5.
6.
2013.09 | V2 | DOC
Amber lighted LED: The power supply is off.
Green lighted LED: The power supply is operating.
Only for units with one power supply: Turn off the unit and unplug the power cord.
Push the release tab (on the back of the power supply) as illustrated.
Pull the power supply out using the handle provided.
Replace the failed power module with the same model.
Push the new power supply module into the power bay until you hear a click.
Plug the AC power cord back into the module and turn on the unit.