7. Check for debris in pump. If
debris is found, blow out with
compressed air.
8. Install insert and rotor.
9. Check gap on rotor. Adjust to
.003"/.004" if needed (see
Figure 16).
Note: Rotate rotor one full turn to
insure the gap is .003"/.004" at
tightest position. Adjust if needed.
(Pump Rotor, continued)
10. Install blades, pump plate, air
filters, and filter end cover.
11. Replace fan guard and upper
shell.
12. Adjust pump pressure (see page
12).
Note: If rotor is still binding,
proceed as follows.
13. Perform steps 1 thru 6 (see page
13).
14. Place fine grade sandpaper (600
grit) on flat surface. Sand rotor
lightly in "figure 8" motion four
times (see Figure 17).
15. Reinstall insert and rotor.
16. Perform steps 10 thru 12 above.

SPECIFICATIONS

WIRING
DIAGRAM
14
Blade
Figure 16 - Gap Adjusting Screw Locations
Output Rating (Btu/Hr.)
Fuel
Fuel Tank Capacity (U.S. Gal.)
Fuel Consumption (Gal. Per Hr.)
Electric Requirements
Amperage (Normal Run)
Hot Air Output (CFM)
Motor RPM
White
White
Green
Spark Plug
Ignitor
Motor
Red
Red
Black
Red
Relay
Gap Adjusting Screw
Rotor
Gap Adjusting Screw
Figure 17 - Sanding Rotor
165,000
Use Only Kerosene or No. 1 Fuel Oil
13.5
1.2
120 volt/60 hertz
4.5
500
3450
Power Plug
120V 60HZ
White
Black
Green
White
White
Blue
Terminal
Board
Photocell
Red
.003"/.004" Gap
Measured With
Feeler Gauge
Sandpaper
B
Flame
Blue
Reset
Out
Button
Control
R
101911