All installations and services must be performed by qualified service personnel.
MODEL
HEAT INPUT RATE (BTUH)
HEATING CAPACITY (BTUH)
BURNER NOZZLE (GPH X
ANGLE, HOLLOW CONE)
OIL PUMP PRESSURE (PSIG)
VENT PIPE SIZE (INCHES)
DESIGN TEMPERATURE RISE (°F)
MINIMUM RETURN AIR TEMP. (°F)
SEASONAL EFFICIENCY
2
(AFUE
*, %)
1
Burner shipped with 0.60x80°A nozzle
2
*AFUE - INCLUDES STEADY STATE THERMAL EFFICIENCY AND OFF CYCLE
LOSSES.
ELECTRICAL RATINGS AND SETTINGS:
ELECTRICAL SUPPLY: 120 VAC / 60HZ / 1 PHASE
MAXIMUM TIME DELAY TYPE FUSE OR HACR BREAKER RATING: 15 AMPS
TOTAL RATED CURRENT (AMPS): 10.3
NOMINAL HEAT ANTICIPATOR SETTING -- 0.2 mA
DIMENSIONS & WEIGHTS:
CABINET: WIDTH - 18 IN., DEPTH – 24-3/4 IN., HEIGHT - 57 IN.
NO.70 MOBILE HOME BASE: WIDTH - 18 5/16 IN., DEPTH - 24¼ IN., HEIGHT - 4 IN.
WARM AIR DUCT: WIDTH – 12 IN., DEPTH – 12 IN., HEIGHT - 14 ¼ IN.
COTTAGE BASE: WIDTH – 18 3/16 IN., DEPTH - 24¼ IN., HEIGHT – 14¾ IN.
FILTER QUANTITY & SIZE: (1) @ 18 IN. x 24 IN. x 1 IN. EA.
APPROXIMATE SHIPPING WEIGHT: 240 LBS.
MANUFACTURER:
MODEL:
AIR TUBE LENGTH (IN.):
HEAD DESIGN:
REFRACTORY TYPE:
OIL PUMP
PRESSURE (P.S.I.G.)

III. FURNACE SPECIFICATIONS

OME-72
Low Fire
70,000
60,000
0.50X80°A
120
4
65
50
86
BURNER DATA
OME-72
R.W. BECKETT CORP.
AFG
3
F-3
ISOFORM (SOFT FIBER)
120
1
High Fire
85,000
72,000
0.60X80°A
8