Download Print this page

Pe Sensor Board/Pe Sensor Lever - Epson Stylus CX3700 Service Manual

Color inkjet printer
Hide thumbs Also See for Stylus CX3700:

Advertisement

EPSON Stylus CX3700/CX3800/CX3805/CX3810/DX3800/DX3850

4.4.15 PE Sensor Board/PE Sensor Lever

External view
L-shaped Tip
Torsion Spring 0.22
2
1
Shaft
Shaft
Straight Tip
PE Sensor Lever
Figure 4-27. Removing PE Sensor Board/PE Sensor Lever
DISASSEMBLY/ASSEMBLY
Groove
PE Sensor Connector Cable
Tab
PE Sensor
Part/Unit that should be removed before removing PE Sensor Board/
PE Sensor Lever
Document Cover / Paper Support Assy. / Scanner Unit / Panel Unit /
Housing, Upper / Printer Mechanism / ASF Unit / Holder Shaft Unit / Spur Gear
36.8 / Extension Spring 0.143 / Clutch
Removal procedure
1.
Remove the shaft of the PE Sensor Lever from the Holder Shaft, and remove
the PE Sensor Lever and Torsion Spring 0.22 in the order as shown in the
figure.
2.
Remove Torsion Spring 0.22 from the PE Sensor Lever.
3.
Release the PE Sensor Connector Cable from the groove of the Holder Shaft.
4.
Release the tab (x1,
from the Holder SHaft.
Fasten the L-shaped tip of Torsion Spring 0.22 to the concave
portion of the PE Sensor Lever, and fasten the straight tip to
the Holder Shaft.
Route the PE Sensor Connector Cable to the groove of the
Holder Shaft so that the Cable does not run off.
Printer Section
) that secures the PE Sensor, and remove the PE Sensor
Revision A
117

Hide quick links:

Advertisement

loading