Pll Unit Adjustment - Icom IC-F7000 Service Manual Addendum

Hide thumbs Also See for IC-F7000:
Table of Contents

Advertisement

5-2 PLL UNIT ADJUSTMENT

ADJUSTMENT
ADJUSTMENT CONDITIONS
LPL LOCK
1
• Operating frequency : 0.5000 MHz
VOLTAGE
• Mode
• Receiving
2
• Operating frequency : 0.4999 MHz
• Receiving
HPL LOCK
1
• Operating frequency : 29.9999 MHz
VOLTAGE
• Mode
• Receiving
2
• Operating frequency : 0.0300 MHz
• Receiving
REFERENCE
1
• Wait for 5 minutes after power ON.
FREQUENCY
• Terminate P5201 on the PLL unit to
ground with a 50 ohms resister.
• Receiving
2
MEASUREMENT
UNIT
PLL
Connect a digital multi
: J3E
meter or oscilloscope
to the check point
CP5301.
PLL
Connect a digital multi
: J3E
meter or oscilloscope
to the check point
CP5401.
PLL
C o n n e c t
voltmeter to the check
point P5201.
Connect a frequency
counter to the check
point P5201.
5 - 3
VALUE
LOCATION
1.0 V
Less than 4.0 V
4.2 V
More than 0.8 V
a n
R F
Maximum level
64.000000 MHz
ADJUSTMENT
UNIT ADJUST
PLL
C5305
Verify
PLL
C5521
Verify
PLL
L5203,
L5204
R5255