3-16 RF filter bandwidth for A/D converter
AB
ABn
This command is used to select the bandwidth of analog filter for the A/D
converter. Normally, it should be set to 10MHz. However, in case of a strong
signal in adjacent frequency, it can be set to 30kHz. This setting does not affect
spectrum display function or FFT search.
To read: AB<CR>
ABn
Response:
3-17 RF band pass filter (for below 25MHz reception)
HN
HNn
This command is to select to use or not use a Band Pass Filter (BPF) for 25MHz
signal. This function is available only to receive 25MHz of frequency.
To read: HN <CR>
HNn
Response:
4. Receive commands
4-1 VFO mode
VF
VFm
RF
RFnnnn.nnnnnn
The VF command is to select VFO A ~ VFO E.
To set the frequency, use the RF command after selecting the VFO.
The VFO-E is used to set receive frequency below 25MHz in the duo receive
mode.
To read: VF <CR>, RF<CR>
VFm,
Response:
RFnnnn.nnnnnn (MHz)
n: 0 , 1
0: 10MHz (recommended) (default)
1: 30kHz
n: 0 , 1
0: Off (No filter) (default)
1: On (Filtered)
m: A ~ E (default: A)
nnnn.nnnnnn (MHz)
Frequency set
(default:0082.500000) (MHz)
30