Summary of Contents for Elation VISION 575

  • Page 1 VISION 575 Version 1.0...
  • Page 2: Table Of Contents

    VISION 575 Table of contents 1. Safety instructions ......................3 2. Operating determinations ..................... 4 3. Description of the device ....................5 4. Installation ........................6 4.1Fitting the lamp ......................6 4.2 Inserting/Exchanging rotating gobos ................. 6 4.3 Rigging the fixture ..................... 7 4.4 Connection to the mains ....................
  • Page 3: Safety Instructions

    CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this device have to: - be qualilfied - follow the instructions of this manual CAUTION!
  • Page 4: Operating Determinations

    2. Operating determinations This device was designed for indoor use only. If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
  • Page 5: Description Of The Device

    3. Description of the device 1 - Fastening screws 2 - Fixation screw for bracket 3 - Bracket 4 - Objective 5 - Mirror Front panel: 6 - DMX Output 7 - DMX Input 8 - Fuseholder 9 - Powercord 10 - Control board Control board: 11 - Display...
  • Page 6: Installation

    4. Installation 4.1Fitting the lamp DANGER ! Install the lamps with the device switched off only. Unplug from mains before ! To insert the lamp (HMI 575) open the cover by loosening the fastening screws at the sides of the cover. Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed for.
  • Page 7: Rigging The Fixture

    (decoration articles, etc.) in between a distance of min. 0,5 m. The VISION 575 can be installed in any position without altering its operation characteristics Install a safety wire that can hold at least 10 times the weight of the fixture. Never use the carrying handles for secondary attachment.
  • Page 8 Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another. Occupation of the XLR-connection: DMX - output DMX-input XLR mounting-socket: XLR mounting-plug: 1 - Ground 1 - Ground 2 - Signal (-) 2 - Signal (-)
  • Page 9: Dmx Protocol

    5. DMX PROTOCOL Channel Channel Value Function Type of control 16 bit 8 bit 0-255 Coarse control of the pan movement proportional Tilt 0-255 Coarse control of the tilt movement proportional Pan fine 0-255 Fine control of the pan movement proportional Tilt fine 0-255...
  • Page 10 Channel Channel Value Function Type of control 16 bit 8 bit Frost,cor. filters,3-facet prism 0-95 Open position (hole) step 96-127 Frost filter step 128-159 3-facet prism step 160-191 3200 K correction filter step 192-223 5600 K correction filter step 224-255 UV filter step 3-facet prism rotation control...
  • Page 11: Addressing

    The VISION 575 is run with a HMI 575 lamp. A relay inside of the VISION 575 allows you to switch On and Off the lamp via itself control board on the front panel or via your controller without affecting the rest of the lighting.
  • Page 12: Rotating Gobo Wheel

    (1 - 10 flashes per second) 7.11 Fan The VISION 575 is cooled by axial fan situated at the rear side of the lighting. The speed of the fan (of course the noice) can be continuously reduced if very quiet performance is required.
  • Page 13: Main Functions

    [Menu] to return to the main menu. In order to reset the counter to 0, you have to hold the [+] and [-]-button and press the [Enter]-button. Power On time By this option you can read the total number of hours that the VISION 575 has been powered On. Press [Enter] or [Menu] to return to the main menu. Switch On/Off the lamp Use the [+] and [-] keys to select "On"...
  • Page 14: Spec -Special Functions

    VISION 575. Press the [Enter] key to run the test program. Reset Function Press [Enter] key to run reset. This option enables the VISION 575 to index all effects (functions) and return to their standard positions. 8.2 SPEC -Special functions Use the [+] and [-] keys to browse through the special functions and select the one by pressing [Enter].
  • Page 15 Lamp On automatically This function enables to switch On the lamp automatically after switching On the fixture. Use the [+] and [-] keys to select "On" if you wish to switch On the lamp automatically after switching On the fixture or "Off" if you wish the lamp off after switching On the fixture and press [Enter] to confirm or [Menu] to cancel and return to the menu.
  • Page 16 575 automatically switch Off the lamp. low/high speed of the fan operating the fan keeps the adjusted low speed until the temperature exceeds max. inside temp.of the fixture, then the VISION 575 automatically switch from low to high the fan speed.
  • Page 17 Default settings Press [Enter] to reset all fixture personalities (not the adjusting functions) to the default values. On the display will appear "rSt" meaning that the fixture makes the reset. See the table of personality setting and their default positions. Default values Personality Display...
  • Page 18 1. Calibration via the control board Press [Enter] and the [+] and [-] keys in order to display the following messages: "Col, SGob, EFEC, rGob, rotG," for very smooth function calibration. Select one of them, press [Enter] and use the [+] and [-] keys in order to adjust their right value from 0 to 255.
  • Page 19: Error And Information Messages

    9. Error and information messages HEAt This message appears if you try to switch on the lamp within 5 minutes after having switched it off (the lamp is too hot). The message will appear on the display if the lamp doesn't ignite within 28 seconds. The VISION 575 will store this information and automatically ignite the lamp when the 5 minutes period has expired.
  • Page 20: Technical Specifications

    10. Technical specifications Power supply: -Voltage......100/115/208/230 V AC, 50/60 Hz ~ -Fuse.......T 5 A@ 230 V -Fuse.......T 10 A@115V -Power consumption..800 VA Motors: -12 high quality stepping-motors controlled by microprocessors Lamp: -HMI 575 Optical system: -Double condensor lens with high efficiency parabolic mirror Beampath: Colours: - 11 interchangeable dichroic-filters plus white...
  • Page 21 Dimmer: -Smooth dimmer from 0 - 100 % Effects: - Special effect wheel with frost filter, color temperature filters 3200 K and 5600 K, UV filter Prisma: - 3 facet prism rotating in both dirrections at different speeds situated on effect wheel Iris: -Motorized iris for different beam diameters Focus:...
  • Page 22: Maintenance And Cleaning