Operating Instructions and Installation
3-2-2(e) Outdoor unit installation
Wiring connection
1. Remove the cover-E parts.
2. Firmly connect the cable connector in the terminal block.
3. Fasten the M4 ring terminal to the hole marked
4. Firmly fix the ass'y cable with clamp wire holder.
5. Assemble the cover-E parts.
6. To prevent the entry of water, form a trap of the ass'y cable as illustrated in the installation
diagram of indoor and outdoor unit.
Installing and Connecting the Outdoor Unit Drain Hose
Drain hole
3-8
Ass'y cover valve (RO Hand cabi, RH)
When using the air conditioner in the heating, ice may accumulate.
Duting de-icing, the condensed water must be drained off safely.
Consequently, you must install a drain hose on the outdoor unit,
following the instructions below.
1. Insert the drain plug into the drain hole on the underside of the
outdoor unit.
2. Connect the drain hose to the drain plug.
3. Ensure that the drained water runs off correctly and safely.
N1 1
2
3