FURNACE SPECIFICATIONS

Heating Data
High Fi re Input¹
High Fi re Output¹
Low-Fi re Steady-Sta te Input¹
Low-Fi re Steady-Sta te Output¹
AFUE²
Tempera ture Ri se Ra nge (°F)
Vent Di ameter³
No. of Burners
Circulator Blower
Ava i l abl e AC @ 0.5" ESP
Si ze (D x W)
Horsepower @ 1075 RPM
Speed
Filter Size (in²)
Permanent
Dis posa bl e
Electrical Data
4
Mi n. Ci rcui t Ampaci ty
Ma x. Overcurrent Device (amps )
Shipping Weight (lbs)
„ Natural Gas BTU/h
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
" FPT
and noise issues.
greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence
over clearances from the enclosure where accessibility clearances are greater.
*MEC96
*MEC96
0302BNA
0402BNA
30,000
28,800
21,000
20,160
96
-
20 - 50
2" - 3"
2
1.5 - 2
10" x 8"
10" x 8"
1/2
5
487
244
8
5
15
111
*MEC96
0603BNA
40,000
60,000
38,400
57,600
28,000
42,000
26,880
40,320
96
96
20 - 50
2" - 3"
2" - 3"
2
3
1.5 - 3
1.5 - 3
11" x 8"
1/2
1/2
5
5
487
731
244
365
8
8
15
15
112
115
*MEC96
*MEC96
*MEC96
0803BNA
1004CNA
80,000
100,000
76,800
96,000
56,000
70,000
53,760
67,200
96
96
35 - 65
35 - 65
2" - 3"
2" - 3"
4
5
1.5 - 3
1.5 - 4
11" x 8"
11" x 10"
1/2
1
5
5
683
853
341
427
8
13.3
15
15
118
140
*MEC96
1205DNA
120,000
115,200
84,000
80,640
96
35 - 65
2" - 3"
6
3 - 5
11" x 11"
1
5
1024
512
13.3
15
154
5