JVC LT-40FH96 Service Manual page 23

Lcd flat television
Hide thumbs Also See for LT-40FH96:
Table of Contents

Advertisement

5.1.6 DETAILS
Self check is performed for the following items:
< Page 1 of screen >
Detection item
Display
Low bias line short
LOB
protection
Fan lock
FAN
Audio
AUD
Devices on the ANALOG
ANA
PWB
Devices on the DIGITAL
DIG
PWB
< Page 2 of screen >
Detection item
Display
Temp. sensor
TEM
Lamp does not light up
L1
Lamp goes out
L2
Abnormal DD CPU
DDT
circuit
Fan lock
FAN
Lamp cover open
LC
Abnormal of optical iris
IRS
5.1.7 METHOD OF DISPLAY WHEN A RASTER IS NOT OUTPUT
In the state where a raster is not output by breakdown of the set, an error is displayed by blink of the POWER LED.
Type of error
Low bias line short protection
MAIN CPU error detection
ATSC TUNER error detection
< Explanation of operation >
If error is detected, the power is turned off.
Shortly after a power is turned off, POWER LED will be blinked.
Power cannot be turned on until the power cord takes out and inserts, after a power is turned off.
Detection content
Confirm the operation of the low bais (16V / 5V /
LCD5V / 3.3V / 1.2V) protection circuit.
Q9601, Q9651[POWER PWB]
Not used
Not used
Confirmation of reply of ACK signal which uses
I2C communication.
IC101, IC102,
IC281, IC381, IC601, IC606,
IC061,
TU001
[ANALOG PWB]
Confirmation of reply of ACK signal which uses
I2C communication.
IC6401,
IC8831
[DIGITAL PWB]
Detection content
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Low luminance blue turnig on and off at 1 second intervals.
Low luminance blue turnig on and off at 2 second intervals.
Low luminance blue turnig on and off at 2 second intervals.
Diagnosis
signal (line)
LB_PRO
Detection starts 3 seconds after
the power is turned on. If error
continues between 200 ms the
power is turned off.
----
----
SDA
If
it
communication is performed and
no reply of ACK signal an error
will be counted.
SDA
If
it
communication is performed and
no reply of ACK signal an error
will be counted.
Diagnosis
signal (line)
----
----
----
----
----
----
----
POWER LED flash cycle
Detection timing
----
----
checks
whenever
I2C
checks
whenever
I2C
Detection timing
----
----
----
----
----
----
----
(No.YA363)1-23