Back Mixing; Range Test; Timer - Spectrum DX6 Instruction Manual

Spectrum 6 channel dsmx telemetry system
Table of Contents

Advertisement

FUNCTION LIST

Back Mixing

Back Mixing applies a mix to all related servos in a wing or tail
type. For example, if you select 2 AIL, 2 FLAP in the Aircraft Type
screen, a mix to one aileron channel affects both aileron servos.
The mix response, however, depends on the aileron channel
included in the mix.
A Back Mix also enables you to use fewer mixes to achieve the
desired response, for example adding roll to a split elevator.

Range Test

The Range Test function reduces the power output. This allows for
a range test to confirm the RF link is operating correctly. Perform
a range check at the beginning of each flying session to confirm
system operation.
To Access the Range Test screen:
1. With the transmitter on and the main or telemetry screen
displayed, press the scroll wheel. The Function list displays.
2. Scroll to highlight Range Test, then press the scroll wheel to
access the Range Test function.
3. With the Range Test screen displayed, push and hold the
trainer button. The screen displays Reduced Power. In this
mode the RF output is reduced allowing for an operational
range test of your system.
4. If you let go of the trainer button, the transmitter will go back
to Full Power.
IMPORTANT: Telemetry alarms are disabled during the
Range Test.

Timer

The DX6 Timer function allows you to program a countdown timer
or stop watch (count up timer) to display on the main screen. An
alarm sounds when the programmed time is reached. You can
program the timer to start using the assigned switch position
or automatically when throttle is raised above a programmed
position. Two internal timers are available that show run time for a
specific model displays on the Main Screen. A total system timer
is also available.
Timer Event and Timer Control Alerts
Press NEXT to select the Timer Event Alerts settings. These
include options for the alerts at every minute for down timers, 1
minute remaining alert, 30 seconds remaining alert, 10 second
to 1 second remining alerts, expiration alert, and every minute up
alert. Press NEXT again to select the Timer Control Alerts settings.
Available options include Timer Start alert, Timer Stop alert, and
Timer Reset alert.
SPEKTRUM DX6 • TRANSMITTER INSTRUCTION MANUAL
Range Testing the DX6
1. With the model restrained on the ground, stand 30 paces
(approx. 90 feet/28 meters) away from the model.
2. Face the model with the transmitter in your normal flying
position and place the transmitter into Range Test mode (see
above). Then push the trainer button; the power output will be
reduced.
3. Operate the controls. You should have total control of your
model with the transmitter in Range Test mode.
4. If control issues occur, contact the appropriate Horizon Product
Support office for assistance.
5. If performing a range test while a telemetry module is active,
the display will show flight log data.
EN



31

Hide quick links:

Advertisement

Table of Contents
loading