FaULT CODEs

DIspLay CODE ON BOILER
Ideal Logic Heat -
User's
DEsCRIpTION
BCC Activation Fault
BCC Fault
Unconfigured PCB
Flame Loss
Fan Fault
Flow Thermistor
Return Thermistor
Outside Sensor Failure
Low Mains Voltage
PCB Fault
Flow/Return Reversed
No Water Flow
Flow Temperature Overheat
or
Unconfigured PCB
Ignition Lockout
5 Boiler Resets in 15 minutes
False Flame Lockout
aCTION
Reset the appliance - if the boiler fails to operate then please contact
Ideal (if under warranty) or alternatively a Gas Safe Registered
Engineer if outside of the warranty period. In IE contact a Registered
Gas Installer (RGII).
Reset the appliance - if the boiler fails to operate then please contact
Ideal (if under warranty) or alternatively a Gas Safe Registered
Engineer if outside of the warranty period. In IE contact a Registered
Gas Installer (RGII).
See Action - Fault Code L 2
Reset the appliance - if the boiler fails to operate then please contact
Ideal (if under warranty) or alternatively a Gas Safe Registered
Engineer if outside of the warranty period. In IE contact a Registered
Gas Installer (RGII).
Reset the appliance - if the boiler fails to operate then please contact
Ideal (if under warranty) or alternatively a Gas Safe Registered
Engineer if outside of the warranty period. In IE contact a Registered
Gas Installer (RGII).
Reset the appliance - if the boiler fails to operate then please contact
Ideal (if under warranty) or alternatively a Gas Safe Registered
Engineer if outside of the warranty period. In IE contact a Registered
Gas Installer (RGII).
Reset the appliance - if the boiler fails to operate then please contact
Ideal (if under warranty) or alternatively a Gas Safe Registered
Engineer if outside of the warranty period. In IE contact a Registered
Gas Installer (RGII).
Contact a qualified electrician or your electricity provider.
Please contact Ideal (if under warranty) or alternatively a Gas Safe
Registered Engineer if outside of the warranty period. In IE contact a
Registered Gas Installer (RGII).
Please contact a Gas Safe Registered Engineer. In IE contact a
Registered Gas Installer (RGII).
Please contact Ideal (if under warranty) or alternatively a Gas Safe
Registered Engineer if outside of the warranty period. In IE contact a
Registered Gas Installer (RGII).
Check system pressure is between 1 & 1.5bar on the pressure gauge.
If the boiler fails to operate then please contact Ideal (if under warranty)
or alternatively a Gas Safe Registered Engineer if outside of the
warranty period. In IE contact a Registered Gas Installer (RGII).
1. Check other gas appliances in the house are working to confirm a
supply is present in the property.
2. If other appliances do not work or there are no other appliances,
check the gas supply is on at the meter and/or pre payment meter
has credit. If the boiler fails to operate then please contact Ideal
(if under warranty) or alternatively a Gas Safe Registered engineer
if outside of the warranty period. In IE contact a Registered Gas
Installer (RGII).
1. Turn power off and on at the fused spur.
2. If the boiler fails to operate please contact Ideal (if under warranty)
or alternatively a Gas Safe Registered Engineer if outside of the
warranty period. In IE contact a Registered Gas Installer (RGII).
Reset the appliance - if the boiler fails to operate then please contact
Ideal (if under warranty) or alternatively a Gas Safe Registered
Engineer if outside of the warranty period. In IE contact a Registered
Gas Installer (RGII).
5