IDEAL LOGIC + Heat 30 User Manual

Hide thumbs Also See for LOGIC + Heat 30:

Advertisement

USERS GUIDE
LOGIC + Heat
12, 15, 18, 24, 30
For installation guide see reverse of book
When replacing any part on this appliance, use only spare parts that you can be
assured conform to the safety and performance specification that we require.
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

Advertisement

Table of Contents
loading

Summary of Contents for IDEAL LOGIC + Heat 30

  • Page 1 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.
  • Page 2 Benchmark Commissioning Checklist. you can check your installer by calling Gas Safe Register direct on 0800 4085500. Ideal stelrad group is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
  • Page 3: Boiler Overheat Protection

    To relight the boiler Repeat the procedure detailed in ‘To light the boiler’. boiler conTrols Legend a. Temperature Control B. Mode Control C. Boiler Status D. Burner ‘on’ Indicator E. Condensate Drain F. Economy Mode 205862-10089 205862-10090 Ideal Logic + Heat - User’s...
  • Page 4: Condensate Drain

    During cold weather, set the boiler stat to maximum, (Must return to original setting once cold spell is over) Place the heating on continuous and turn the room stat down to 15ºC overnight or when unoccupied. (Return to normal after cold spell). Ideal Logic + Heat - User’s...
  • Page 5: Points For The Boiler User

    The boiler has a call for heating but the appliance has reached the desired temperature set on the boiler. The boiler is operating in heating mode. The boiler is operating in frost mode. continued ..Ideal Logic + Heat - User’s...
  • Page 6: Fault Codes

    Check system pressure is between 1 & 1.5bar on the pressure gauge. Flow Temperature Overheat If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the Unconfigured PCB warranty period.
  • Page 7 Ideal Logic + Heat - User’s...
  • Page 8 Ideal stelrad group pursues a policy of continuing improvement in the design and performance Ideal Consumer Helpline of its products. The right is therefore reserved to vary specification without notice. Tel: 01482 498660 Ideal, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN.

This manual is also suitable for:

Logic + heat 15Logic + heat 12Logic 30Logic 12Logic 24Logic 15 ... Show all

Table of Contents