Insert the gland housing in to the BSM-3 case and secure with nut.
7.
Pass the gland securing nut over the bare wires and along the cable.
8.
Pass the cable through the gland housing.
9.
Terminate the wires to the terminal blocks according to the terminal
specification in the following pages
10.
Connect the terminal blocks to the corresponding connector block
11.
Tighten the cable gland outer sealing nuts by hand
12.
Close the BSM-3 cover and secure the cables.
Port
Transducer 1&2
Power
Speed
Temperature 1
Temperature 2

Airmar transducers

The wiring diagram below shows how to connect an Airmar
transducer (B265).
¼ Note:
On some models Low frequency XDCR+ wire (blue/white) can
be yellow.
On some transducer models temperature brown cable is connected
internally to XID GND, and there is no need to connect bare and
brown cable together.
Transducer connection |
Gland size Cable diameter
M20
10.0 mm - 14.0 mm (3.94" - 5.51")
M16
6.0 mm - 10.0 mm (2.36" - 3.94")
BSM-3 Installation Manual