3.18 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
3.18 [1-1] Slot—Card Property - T1 type
(KX-TDA100/KX-TDA200/KX-TDA600 only)
The properties of the T1 card can be specified.
Line Coding
Selects the line coding type of T1 PCM (Pulse Code Modulation) used.
Value Range
B8ZS, AMI
Maintenance Console Location
3.18 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Frame Sequence
Selects the type of frame sequence used for communications.
Value Range
D4, ESF
Maintenance Console Location
3.18 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
ESF Frame Sequence
Selects the values for C-bit and D-bit. To enable this setting,
set to ESF.
Value Range
C=A, D=B; C=0, D=0; C=0, D=1; C=1, D=0; C=1, D=1