Capabilities will vary according to Kilowatt Derating
following.
Motor
Starting
Requirements
(In-Rush)
(HP)
1/4
1/3
1/2
3/4
1
2
3
Figure 6-1. Motor Requirements
Will Operate Air
Conditioner of
Model
Wattage
Size Indicated
4CZ
4000
One 13,500 Btu
6.5 CZ 6500
One 13,500 Btu
Two 13,500 Btu
Figure 6-2. Air Conditioner Requirements
(50 Hz units will have slightly lower "power
to spare" figures than those indicated)

Appliance Loads

Marine generator sets are often used to furnish AC for
appliances such as TV, stereo, electric water heaters,
etc. With the exception of the resistance-type loads
such as the water heater, requirements for appliances
are usually low. Such loads must not, however, be
overlooked when figuring total requirements. Reserve
capacity should be available for anticipated appliance
loads to avoid overloading of a set. The average power
requirements of some common electrical appliances
are given in Figure 6-3.

Kilowatt Derating

Units are rated as listed below at 1.0 power factor.
Derate the listed rating by approximately 3.5% per 1000
ft. (300 m) when the unit is operated at altitudes of 500 ft.
(150 m) or more above sea level.
6-2 Installation
Running
Watts
Watts
750
1000
1500
2000
3300
4000
5000
"Power to
Spare" for
Lighting
Appliances,
Tools
3.5CFZ, 50 Hz: 3.5 kW at 77_ F (25_ C) and 3.5 kW at
122_ F (50_ C).
4CZ, 60 Hz: 4 kW at 77_ F (25_ C) and 3.5 kW at 122_ F
(50_ C).
5CFZ, 50 Hz: 5 kW at 77_ F (25_ C) and 4.85 kW at
330
122_ F (50_ C).
400
600
6.5CZ, 60 Hz: 6.5 kW at 77_ F (25_ C) and 6 kW at 122_ F
(50_ C).
750
1100
2000
Electrical
Appliance
3000
Automatic Pilot
Blanket, Electric
Blender
Broiler
Depthometer
Drill, 3/8"
2100
Dryer, Hair
4600
Fan, Air
2700
Circulating
Food, Mixer
Heater, Space
Heater, Water
Iron
Light Bulbs
Pan, Frying
Percolator,
Coffee
Radar
Radio
Radiophone
Range, Electric
(per element)
Soldering Gun
Television
Toaster
Water System
Figure 6-3. Appliance Average Wattage Ratings
Motor
Starting
Running
Watts
--
150--250
--
800
--
--
25--1000
600
--
850--1200
50--200
400
--
750--1500
--
--
900--1200
--
(as indicated)
--
--
--
750--1500
--
--
100--200
--
1000--1500
--
--
300--750
--
750--1200
500--1500
300--1250
(60 Hz)
TP-5695 12/93
Watts
50--250
600
1350
350
25--100
235
1500
1200
650
50--100