Remote Start and Four-Meter
Panel Kit
Allows starting-stopping from a location remote of the
generator set. The illuminated gauges include a DC
voltmeter,
engine
oil
temperature gauge, and generator running time
hourmeter. Generator sets come equipped with a 6-pin
connector on controller bottom for connection of the kit.
See Figure 2-7 for remote start and four-meter panel
features.
Start/Stop Switch is a rocker-type switch with " ON"
light used to start and stop the generator set.
6
5
1. Engine Oil Pressure
2. Hourmeter
3. Voltmeter
TP-5695 12/93
pressure
gauge,
water
1
Figure 2-7. Remote Start and Four-Meter Features
DC Voltmeter measures voltage of starting battery(ies).
Normal battery operating range is 12--14 volts.
Engine Oil Pressure Gauge measures engine oil
pressure. Normal engine operating range is 30--50 psi
(207--345 kPa).
During the engine break-in period, it is normal for the
engine to produce higher oil pressure readings.
Water Temperature Gauge measures engine coolant
temperature. Normal engine operating range is
170--195_F (77--91_C).
Hourmeter records total generator set operating hours
for reference in maintenance scheduling.
4
4. Water Temperature
5. Start/Stop Switch
6. " ON"Light
NOTE
2
3
Operation 2-7
1-830