The following values are displayed per entry:
- Fixed day (storage date))
- Yearly performance factor
- Supplied heat for heating
- Supplied heat for DHW
- Employed energy for heating
- Employed energy for DHW
Displayed are the supplied and used energy values over the course of a year (or
between two fixed day entries).
The fix day storage can be deleted as a whole (all entries) via parameter 3190.
Fixed day yearly performance factor
Line no.
Operating line
3119
Fixed day yearly performance factor
The parameter Fixed day yearly perf fact sets the fixed day (day / month).
An entry is generated in the storage at mid-night of the entered, fixed day. The process
is repeated annually. The fixed day cannot be deactivated.
Counter values
The counter values displayed in the fixed day storage are the energy values recorded
over the time period between the two fixed day entries which are used to calculate the
associated yearly performance factor.
Supplied and employed energy for heating and DHW is displayed separately.
Up to 10 entries (10 years) can be stored in the fixed day storage. The first entry (Index
1) is always the latest and drops the older entries in the index by one position. The
counter value "---" is displayed if the storage entry is empty.
Overview of the corresponding operating lines:
Fixed
Fixed day &
yearly perf
day
factor
storage
1. Year
3120
2. Year
3127
3. Year
3134
4. Year
3141
5. Year
3148
6. Year
3155
7. Year
3162
8. Year
3169
9. Year
3176
10. Year
3183
Yearly performance factor
based on the following definitions:
The yearly performance factor is a quotient from supplied energy (E
energy (E
) over a period of one year. The gain consists for the energy derived from
ein
the environment (E
).
um
User manual RVS61.843, RVS41.813
6 The settings in detail
Delivered
Delivered
heat for
heat for
heating
DHW
3121
3122
3128
3129
3135
3136
3142
3143
3149
3150
3156
3157
3163
3164
3170
3171
3177
3178
3184
3185
The performance factor and yearly performance factor are
Employed
Employed
energy
energy
heating
DHW 1
3124
3125
3130
3131
3137
3138
3144
3145
3151
3152
3158
3159
3165
3166
3172
3173
3179
3180
3186
3187
) and employed
ab
CE1U2355en_02
28. September 2009