Download Print this page

Adapting Blower For Recirculation - GE JVM3150 Installation Instructions Manual

Over the range microwave oven
Hide thumbs Also See for JVM3150:

Advertisement

Available languages

Available languages

C3.
ADAPTING BLOWER
FOR RECIRCULATION
NOTE: The exhaust adaptor with damper is not
needed for recirculating models. You may want to
save them for possible future use.
1
Remove and save screws that hold blower plate and
blower unit to the oven.
Blower Plate Screws
Slide the blower plate from under its retaining
2
flange and lift it off.
Retaining
Flange
Carefully pull out the blower unit. The wires
3
will extend far enough to allow you to adjust the
blower unit.
Installation Instructions
Blower Plate
Back of
Oven
Blower Motor Screw
Blower Plate
4
Roll the blower unit 90° so that fan blade openings
are facing toward the front of the oven.
BEFORE: Fan Blade
Openings Facing Up
AFTER: Fan Blade
Openings Facing
Forward
20
Roll

Hide quick links:

Advertisement

Chapters

loading

This manual is also suitable for: