Location Requirements

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from refrigerator.
Failure to do so can result in death, explosion, or fire.
IMPORTANT:
Observe all governing codes and ordinances.
It is recommended that you do not install the refrigerator near
an oven, radiator, or other heat source.
Do not install in a location where the temperature will fall
below 55°F (13°C).
Floor must support the refrigerator weight, more than 600 lbs
(272 kg), door panels and contents of the refrigerator.
Ceiling height must allow for side tipping radius. See "Tipping
Radius."
Location should permit door to open fully. See "Door Swing
Dimensions."
Location must permit top grille removal. See "Opening
Dimensions."
Opening Dimensions
The width of the opening, from side to side, must be as
specified for your model, for at least 2" (5.08 cm) back from
the face of the cabinet.
NOTE: If your opening does not meet this requirement, you
will need to make modifications.
A solid soffit or wall cabinet must be installed 84" (213.4 cm)
above the floor. If the solid soffit is higher than 84" (213.4 cm)
or one is not available, then the refrigerator must be braced.
Handle Side Door Trim
W10167367 - SxS
W10188556 - BM (Left)
W10202604 - BM (Right)
W10202478 - FDBM (Right)
W10202480 - FDBM (Left)
Panel templates
W10222280 - SxS
W10222278 - Bottom Mount
W10222282 - Grille
If the anti-tip boards are needed, they must be attached to the
rear wall studs so that there is 84" (213.4 cm) from the bottom
of the anti-tip board to the floor. See "Install Anti-Tip Boards"
for more information.
For a fully integrated installation, a minimum of 6" (15.24 cm)
of open space above the refrigerator is required. See "Fully
Integrated Installation." Anti-tip boards are required. See
"Install Anti-Tip Boards" for more information.
A grounded 3 prong electrical outlet should be placed within
4" (10.2 cm) of the right side cabinets or end panel. See
"Electrical Requirements" for more information.
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. If the water shutoff valve is not in the cabinets, the
plumbing for the water line can come through the floor. See
"Water Supply Requirements" for more information.
80" - 90"
(203-229 cm)
84" (213.4 cm)
to bottom of solid soffit
(see chart following)
B
6"
(2.54 cm)
(15.2 cm)
Model Width A (as shown above)
42
42" (106.7 cm)
48
48" (121.9 cm)
Installation Type
Standard Flush
(new installation)
Retrofit Installations
4"
(10.2 cm)
77"
(196 cm)
A
Width
1"
6"
(15.2 cm)
Depth B (as shown above)
25" (63.5 cm) minimum
24" (60.9 cm) minimum