53 And 79 Usg (200 And 300 Liter) Tank Installation; Thermal Insulation And Thermometer Installation - Viessmann VITOCELL 300 EVI Series Installation Instructions Manual

Vitocell 300 evi series indirect-fired domestic hot water storage tank
Hide thumbs Also See for VITOCELL 300 EVI Series:
Table of Contents

Advertisement

Set-up and Connections

53 and 79 USG (200 and 300 Liter) Tank Installation

Thermal insulation and thermometer installation

All required components are included in the insulation
jacket carton.
Note: the 53 and 79 USG (200 and 300 L) tank comes
with the insulation jacket installed.
8
Vitocell 300-V Installation Instructions
1. Level the DHW tank with its leveling bolts.
IMPORTANT
Do not extend the leveling bolts beyond an overall
length of 1½ in. (35 mm).
2. Remove top cover and the thermal insulation blanket.
3. Insert the thermometer sensor into the tank cap hole
as far as it will go.
4. Secure the sensor with a spring clip. Install the top
cover and the thermal insulation blanket.
IMPORTANT
Never wrap insulating tape around the sensor.